Startup
YarnMaster PRISMA
www.loepfe.com
25
1. Switch off the machine.
2. Disconnect the machine’s compressed air supply.
3. Release the pressure from the machine’s compressed air system
4. Remove the spindle cover.
5. Install the sensing head on the spindle.
6. Connect the machine’s compressed air supply.
7. Connect the sensing head to the integrated spindle adapter.
8. Replace the spindle cover.
PIN
Loepfe label
max. A
10
7 V (± 0.5 V)
0.25
9
5 V (± 0.5 V)
0.20
8
54 V (+8/(−10) %)
0.15
7
GND
6
SPINDLE_STATUS
5
SPINDLE_RXD
4
SPINDLE_TXD
3
LoepfeBus_A
2
LoepfeBus_B
1
SPINDLE_DRUM_PULSE
4.7
Software installation wizard
4.7.1
Set basic settings
The default settings can be modified later at any time.
The installation wizard walks you through the basic settings step by step.
ü
The software has been installed.
1. Plug the LZE into mains power.
ð
The LZE starts up.
ð
The
«Welcome»
window opens.