FAN MAINTENANCE (IF FITTED)
Only the manufacturer, its service agent or a similarly qualified person should remove the fan
box to carry out fan installation, servicing and maintenance.
The fan should need little attention
other than occasionally (perhaps once a year) removing it to clean dust and lint from the impeller.
First unplug the mains lead from the power point.
Withdraw four screws on the rear faces of the back legs and lower the fan box clear of the heater.
Clean the impeller blades carefully by blowing or vacuuming, and reassemble.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or
similarly qualified person in order to avoid electrical hazard.
CLEANING THE FLUE
This may be needed about once a year or more frequently under adverse conditions. Signs of creosote
and soot build-up are inadequate draught, smoking when the door is opened and a dull thud when the
outside of the flue is tapped. A blocked flue can be cleaned only by sweeping. DO NOT USE
CHEMICAL CHIMNEY CLEANERS.
FLUE INSPECTION
Check regularly that the flue is sound, particularly the metal base of enamelled flues.
BEFORE EACH HEATING SEASON.
To ensure continued safety, check the condition of the following items; the flue system (particularly the
flue sections nearest the firebox), the firebox top baffle, the firebox liners and the door gasket.
Replace parts only with genuine LOGAIRE spares.
Australia Distributor:
New Zealand:
Glen Dimplex Australia Pty Ltd
Glen Dimplex Australasia Ltd
Unit2, 205 Abbotts Rd, Dandenong
P.O. Box 58-473 Greenmount,
Melbourne, Victoria 3195
Manukau 2141, Auckland
For your own records, please complete the following:
Manufactured in PRC
11
Model:
Serial Number:
Retailer:
Purchase date:
Summary of Contents for Talisman
Page 1: ......