SPACE 2000 (T and M versions) OPERATION MANUAL
21
Radius - diameter switching
(only T version)
This function enabled only in the SPACE 2000 T version switches the display of
the X-axis (diametral axis) from radius to diameter and vice-versa.
With diameter displayed on the X-axis display, the "DIA" LED lights up.
Necessary conditions:
a SPACE 2000 T version must be present.
the SPACE 2000 must be set in position display conditions ("POS" LEDs on).
Select the function by pressing the
following keys :
The
“F7”
message
appears on
the X-axis display to indicate the
choice of the function to be
enabled. All the LEDs except PWR
and the displays of the other axes
are switched off. The indication of
the origin/tool remains enabled.
In order to quit this selection and
return to the position display, press
the key :
In order to enable the function
selected press:
The
“DIA ON”
message appears
on the X-axis if the "radius" display
condition was enabled; otherwise
the
“DIA OFF”
message appears
if "diameter" display condition was
enabled.
The “DIA” LED on the X-axis will
light up if the display is in
“diameter” condition.
Carefully check the conditions of
the “DIA” LED on the X-axis in
order to avoid committing serious
errors during working.
F
7
F
E
nt
F
7