SPACE 2000 (T and M versions) OPERATION MANUAL
28
P08 = Zero achieved signal operation mode
The zero achieved signal is an optional that requires hardware variations in the
main board.
The values that can be programmed for this parameter are as follows :
0
=
The zero achieved signal is enabled by the passage of the
display over the “0" value and maintained for the period of
time set with parameter P09
1
=
The zero achieved signal is enabled by the passage of the
display over the “0" value and maintained until it shifts
positively or negatively from the "0" point by the space defined
with parameter P09
P09 = Numerical value that defines P08 mode
The value that can be programmed runs from 0000 to 9999.
With P08 = 0
– Each P09 unit corresponds to 20 ms
With P08 = 1
– Each P09 unit corresponds to the value of the transducer pulse
defined for the axis in which the zero achieved signal is enabled.