SPACE 2000 (T and M versions) OPERATION MANUAL
29
INDEPENDENT PARAMETER FOR AXIS
P10 - P20 - P30 - P40 = Enabling
The coherent values for this parameter are:
0
/
1
With parameter Px0, the SPACE 2000 defines axis disabling with the “0” value
and axis enabling with the "1" value.
For the X-
axis (P10), the SPACE 2000 accepts only the value “1” because this is
the axis for dialogue with the user.
P11 - P21 - P31 - P41 = Counting direction
The coherent values for this parameter are:
0
/
1
With parameter Px1, the SPACE 2000 defines no inversion in the counting
direction with the "0" value and counting direction inversion with the "1" value.
P12 - P22 - P32 - P42 = Display format
This parameter is composed of two numbers separated by a decimal point.
The first number indicates the digits to the left of the decimal point (integer) and
the second number indicates the digits to the right (decimal) that must be shown
on the display.
All combinations are possible except:
-
values in which the sum of the two numbers exceeds “7” (the maximum number
of digits)
-
values in which the first number is equal to “0” (the minimum number of the
integer digit = 1)
Example :
P12= 5.2
X-
axis display
X
00000.00
P22= 4.3
Y
-axis display
Y
0000.000
P32= 4.2
Z
-axis display
Z
0000.00
P12= 7.0
X
-axis display
X
0000000
(only integers)
P12= 5.3
Par. inc. (Incoherent parameter)
P22= 0.7
Par. inc. (Incoherent parameter)
P13 - P23 - P33 - P43 = Resolution factor - integer part
The range of coherent values runs from:
0000
to
9999
P14 - P24 - P34 - P44 = Resolution factor - decimal part
The range of coherent values runs from:
0000
to
9999
Resolution factor
The resolution factor is composed of the union of the two parameters above: the
integer part and the decimal part, and is strictly linked to the display format (P12 -
P22 - P32 - P42).