17B
-
7
PETROL INJECTION
Oxygen sensors
K7M, and 710
17B
REMOVAL
I -UPSTREAM OXYGEN SENSOR
Remove:
- the exhaust manifold heat shield,
- the upstream oxygen sensor connector from its
support by sliding it (in the direction of the arrow).
Disconnect the upstream oxygen sensor connector.
Remove oxygen sensor using the tool (Mot. 1495).
Essential special tooling
Mot. 1495
22 mm oxygen sensor
removal / refitting soc-
ket - 1/2" square drive
and a 24 mm Allen key
Tightening torques
m
oxygen sensors
4.5 daNm
heat shield mounting
nuts
2.5 daNm
108426
107925