17B
-
10
PETROL INJECTION
Oxygen sensors
K7J, and 710
17B
II - DOWNSTREAM OXYGEN SENSOR
Mount the vehicle on a lift.
Remove the downstream oxygen sensor connector
from its support by sliding it (in the direction of the ar-
row).
Disconnect the connector of the downstream lamb-
da sensor.
Remove the lambda sensor.
REFITTING
Proceed in the reverse order to removal.
Torque tighten:
- the oxygen sensors (4.5 daNm) using the tool
(Mot. 1495),
- the heat shield mounting nuts (2.5 daNm).
108424