indicated by a box symbol appearing after the preset number. Press the Recall Button again to
activate the Preset. Pressing any other button will cancel the operation.
Preset Name
Recall 32 My System
a
b
c
SELECT PRESET
TO RECALL
a
RECALL
RECALL
Users can develop their own Preset based on one of the Basic or Factory Preset
s
stored within
the device. Once a basic or user Preset has been recalled, a user has complete freedom to
adjust any or all of the parameters. Factory Preset
s
can be used as the basis for user Presets
but they have some parameters that are predefined as a function of the loudspeaker system.
These parameters are ‘hidden’ from the user, as they should be constant regardless of
application.
Preset Store
To store the current Preset in a user location, press the Preset Store Button so the indicator
above it illuminates. Turn the first parameter knob until the required Preset location number is
show on the display. A Preset name of up to 12 characters in length can be entered using
parameter knobs B and C. Pressing the Store Button again completes the process and stores the
Preset. As with Preset Recall, pressing any other button cancels the operation.
Preset Name
Store 32 My System
a
b
c
SELECT STORE
LOCATION
a
STORE
STORE
c
b
NAME PRESET