Parameter 7, Parameter size 1 byte. Pushbutton 1 functionality.
This parameter specifies the functionality of pushbutton 1. For a further description, see chapter 6.4.
Value
Description
0
Standard toggle-function, the state is switched between on and off, dimming up and down.
(Default)
1
Always turn off or dim down. Using this parameter, the pushbutton can only send ‘off’ or
‘dim
down’ commands. Use this in pair with another pushbutton with value
2.
2
Always turn on or dim up. Using this parameter, the pushbutton can only send ‘on’ or ‘dim up’
commands. Use this in pair with another pushbutton with value 1.
3
When the pushbutton is down; an on command is sent, and when the pushbutton is released; an
off command is sent.
Parameter 8, Parameter size 4. Switch Multilevel Set single-activation values for pushbutton 1.
This parameter specifies the value that are sent to the devices in the Switch Multilevel association group (group 3)
when the pushbutton is single-pressed.
Value
Description
Byte 1: Enable / Disable
0
Disabled
–
A single activation of the pushbutton will not send commands to devices in the
association group.
1
Enabled
–
A single activation will send commands to devices in the association group. Devices
will receive commands with the values set in 3 following bytes. (Default)
Byte 2: Upper switch value
0
–
99,
255
When single pressing the pushbutton for ON, a Switch Multilevel Set with this value will be send
to devices in the association group. (Default = 255)
Byte 3: Lower switch value
0 - 99
When single pressing the pushbutton for OFF, a Switch Multilevel Set with this value will be send
to devices in the association group. (Default = 0)
Byte 4: Duration
0 - 255
When single pressing the pushbutton the Switch Multilevel Set with this duration value will be
send to devices in the association group.
0
: Use dimmer default timer value. (Default)
1
–
127
: Duration in seconds.
128
–
255 : Duration in minutes (minus 127) from 1
–
128 minutes, where 128 is 1 minute.