Power consumption
The table below shows detailed information about the typical power consumption for the RTCU
NX-910 device while it is running.
DC power consumption: Device operating in normal mode
12V
24V
BAT
Device active
70
35
180
mA
Device active with Cell on*
110
55
300
mA Idle @ -63dBm* (2G)
Device active with GPRS session*
300
120
800
mA -65dBm, Battery not
charging*
Device active with Ethernet on
100
45
310
mA Connected to switch, in idle
Device active while charging
620
310
-
mA
Note:
Values marked with (*) is average and should be considered as guidelines as they may vary
depending on the cellular signal strength.
Note:
Power consumption from a fully charged battery.
AC power consumption: Device operating in normal mode
220V AC
Device active
1
W
Device active with Cellular on*
2.5
W
Idle @ -63dBm* (2G)
Device active with GPRS session*
4
W
@ -65dBm, Battery not
charging*
Device active with Ethernet on
1.5
W
Connected to switch, in idle
Device active with RF sending.
3.5
W
Device active while charging
9
W
Note:
Values marked with (*) is average and should be considered as guidelines as they may vary
depending on the cellular signal strength.