6. Requirements on safe operation and electromagnetic
compatibility.
While using the device for the specified purpose (the transmitting unit of the device is switched
on, about which the LED indicator on the casing of BAPP signals), one may not set the antenna units
to the people. Safety of SK «Oko-2» when the standard position of the device is observed (BAPP is
set to the investigated cargo and is moved along or under the surface at the distance of up to 0.1 m
from the surface of the cargo) is confirmed by the conclusion of the sanitary supervision and disease
control of Center for Sanitary and Epidemiological Supervision of CSSS of the Russian Ministry of
Health dated 03.07.2007
г
.
№
50.99.04.431.
П
.008785.07.07.
•
One may not sink the device or its separate parts into water or any other liquids.
•
One should avoid (exclude) heavy blows and mechanical damages in running or transporting
the device.
•
The device does not distribute electromagnetic interference (noise) higher than a permissible
noise level.(See Sanitary Certification).
7. Technical
maintenance.
7.1 General
instructions.
1.
During technical maintenance some preventive maintenance is performed to maintain the proper
condition of the device and to provide its normal operation within the service life (8 years).
2.
Recommended frequency and types of technical maintenance:
3.
External examination – before each running – no damages incompatible with the operation -
isolation damages, cracks and so on may not be available on the case of the device and connecting
cables;
4.
External cleaning – once in three months – decontamination of the device and split connectors
surface;
5.
Battery charging PU 3,8/12 – not less than one time in 3 months-including power supply units
included in tools, parts and accessories ZIP-0, working as required.
7.2 Maintenance
procedure
During the external examination of the device you should test the fastening BUOI, BP and
BAPP to a folding handle rod, paint–and-lacquer coating condition, lack of chips and cracks on the
parts made of glass-fiber material and plastic, as well as on painted parts.
Battery charging PU 3,8/12 is to be performed at reduced voltage 10.5 V, but not less than once
in 3 months ( including Power Unit(PU) from the accessories ZIP-0).