5  PRODUCT

Chapter 5.2 shows a standard model of the ACS-CB-SENS Collision Sensor, including additional products. 
The exact variant of the ACS-CB-SENS is denoted by the product's order code. Consult the accompanying 
data sheet to ensure that you have received the correct variant. 

5.1  ABOUT INTELLIGENT SYSTEM PROTECTION

Intelligent System Protection (ISP) is LOGICDATA’s collision detection system. It aims to reduce the risk of 
system damage when using LOGICDATA products. When a collision is detected, all Actuators stop immedi-
ately and move back slightly in the opposite direction (Drive Back Function). The following points must be 
observed regarding the ISP function: 

•  ISP sensitivity and ISP shutdown values depend on the complete system (mechanical and electronic 

components). Contact LOGICDATA to determine the ISP suitability of your Table System. 

•  If no mechanical brake is installed, ISP shutdown sensitivity will be reduced when the table is loaded. 

However, if there is no load on the table top, ISP will function properly without a brake.

•  After ISP is activated, the next movement of the system can only be in the opposite direction. 
•  ISP shutdown values can be adjusted in the system parameters. Contact LOGICDATA for further details. 

5.2  KEY PRODUCT FEATURES 

LOG-PRT-DMS

1

Collision Sensor

2 Cable

3 RJ10 Connector

4 DMS Cover (purchased separately)

ACS-CB-SENS

1

ACS-CB-SENS Processing Unit

2 Mounting Points

3 RJ Ports (for LOG-PRT-DMS)

4 DIN Port (for LOG-CBL-CB-SENS)

5 LOG-CBL-CB-SENS Connection cable

4

2

3

1

4

1

3

5

2

Summary of Contents for ACS-CB-SENS

Page 1: ...MANUAL Document Version 3 0 March 2020 ACS CB SENS Valid for LOG PRT DMS 300 LOG PRT DMS LD DMS Cover...

Page 2: ...3 0 March 2020 This document was originally published in English LOGICDATA Electronic Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone 43 0 3462 51 98 0 Fax 43 0 3462...

Page 3: ...2 7 Residual risks 8 2 8 Skilled Persons 8 2 9 Notes for Resellers 9 3 Scope of delivery 9 4 Unpackaging 9 5 Product 10 5 1 About Intelligent Sensor Protection 10 5 2 Key Product Features 10 5 3 Dimen...

Page 4: ...4 7 System Information 16 8 Additional Information 17 8 1 Software Dependent Functions 17 8 2 Disassembly 17 8 3 Maintenance 17 8 3 1 Cleaning 17 8 3 2 Replacing a Collision Sensor 17 8 4 Troubleshoo...

Page 5: ...rchase and full payment of the product all text and images in Chapter 2 Safety may be used free of charge by the customer for 10 years after delivery They should be used to prepare end user documentat...

Page 6: ...lly Height Adjustable Tables It is installed by Resellers into Height Adjustable Table systems It is used to recognize collisions between the Table System and other objects It is intended for indoor u...

Page 7: ...es INFO Indicates important tips for handling the product 2 6 LIABILITY LOGICDATA products comply with all currently applicable health and safety regulations However risk can result from incorrect ope...

Page 8: ...lision Sensor in potentially explosive atmospheres CAUTION Risk of minor or moderate injury through tripping During the assembly process you may have to step over Cables Tripping over Cables may lead...

Page 9: ...ctions that end users require to handle the product safely They must also include an instruction to always keep the Operating Manual in the immediate vicinity of the product INFO No unauthorized perso...

Page 10: ...ing the ISP function ISP sensitivity and ISP shutdown values depend on the complete system mechanical and electronic components Contact LOGICDATA to determine the ISP suitability of your Table System...

Page 11: ...op 30 0 mm 1 181 Fig 1 Product dimensions ACS CB SENS 5 4 DIMENSIONS LOG PRT DMS Length 48 3 mm 1 902 Width 31 8 mm 1 252 Height to underside of Table Top 29 0 mm 1 142 Fig 2 Product dimensions LOG PR...

Page 12: ...generally accepted standards and guidelines of electrical engineering and furniture manufacturing Read all instructions and safety advice carefully CAUTION Risk of minor or moderate injury through tr...

Page 13: ...prod uct s datasheet 6 4 MOUNTING THE ACS CB SENS NOTICE Ensure the ACS CB SENS is mounted in a place from which the cables can easily reach the Control Box and LOG PRT DMS Sensor Stretching or strain...

Page 14: ...fications INFO LOGICDATA recommends a tightening torque of 3 Nm for the connection to the Crossbar and 2 2 5 Nm for the connection to the table top depending on material used 1 Place the surface of th...

Page 15: ...the specific function or circuit characteristic the connector or terminal is used for INFO If your system is not parametrized to support Intelligent System Protection you will need to alter the parame...

Page 16: ...e ACS CB SENS Fig 6 3 Insert the cranked 8 pin cable into the Port on the top of the Control Box Fig 7 4 Reconnect the Control Box to the power source Fig 6 Connecting the LOG CBL CB SENS to the ACS C...

Page 17: ...nauthorized spare or accessory parts may cause system damage Warranty claims are void in this scenario 8 3 1 CLEANING 1 Disconnect the Control Box or DYNAMIC MOTION system from the mains 2 Wait 30 sec...

Page 18: ...rk 18 8530 Deutschlandsberg Austria Phone 43 0 3462 5198 0 Fax 43 0 3462 5198 1030 Email office at logicdata net Internet http www logicdata net LOGICDATA North America Inc 5300 Broadmoor Ave SE Suite...

Reviews: