Logicube SuperSonix User Manual
11
2. Getting Started (Fast Start)
Applying power to the Logicube SuperSonix
Calibrating the Color Touch Screen
The Color Touch Screen recalibration process is very
simple and is outlined for you in the procedure below:
1. Place a finger on the touch screen while
plugging in the power adapter.
2. Keep you finger on the screen until the unit
boots to a screen that reads
Touchpad
Calibration
.
Please touch center of the square
with finger
(1/5).
3. Locate a square at the top of the screen and
touch it with your finger.
4. Repeat the previous step four more times.
The unit will count each time the square is
tapped correctly. It will count (1/5), (2/5), etc.
5. Once the screen has been calibrated, it will
reboot to the Main Menu Screen.
6. The SuperSonix will retain the calibration
setting until the next recalibration.
The Logicube SuperSonix is able to detect whether a
PATA (IDE) or SATA drive is attached to the Master
or Target position. The unit is capable of cloning
to/from a SATA drive to a PATA drive and vice versa
(as well as PATA to PATA and SATA to SATA).
NOTE
: Never attach both a PATA (IDE) and
SATA drive to the Master or Target position. The
unit can only handle one drive on each position.
Before applying power perform the steps listed below.
Connecting PATA (IDE) Drives
1. Open the Logicube SuperSonix by pressing
the two latches on the left side of the unit and