IMAGING
Logicube ZX-
Tower™ User’s Manual
21
values each pass will be written on each of the passes
selected.
–
This will open the HPA/DCO option for wiping. If
the drive to be wiped has HPA and/or DCO that needs to be
wiped, select
Yes
for the corresponding option.
–
By default, this is set to 100% which will wipe all
Logical Block Addresses (LBAs) and will wipe the entire drive
(100%).
–
This Wipe Setting will change depending on the
Wipe Pattern
Mode
selected.
If
None
was selected, this is not selectable.
If
DoD
was selected, the first six pass values will be filled
automatically by default. It is mandatory that the user
enter the 7
th
pass value by tapping the icon or the
operation will fail.
When DoD is selected, the ZX-T automatically
enters default values for pass numbers 1 through
6. It is mandatory that the user enters a value for
the 7
th
pass or an error will appear and the ZX-T
will not proceed with the wipe operation. Values
can be changed or added by tapping the
icon.
If
Custom
was selected, no passes will be filled out.
It is
mandatory that the user set the value for at least one
pass or the wipe operation will fail. The pass value can
be set by tapping the
icon.
When Custom is selected, there is no default
value entered for any passes. It is mandatory that
the user select a value for at least the first pass or
an error will appear and the ZX-T will not proceed
with the wipe operation. Values can be changed
or added by tapping the
icon.
Editing one or more of the passes in DOD or CUSTOM mode will
bring up some options:
SKIP –
Instructs the ZX-T to skip the pass.
RANDOM –
Instructs the ZX-T to perform a random
pattern or value.
Summary of Contents for ZX-Tower