UNPACKING

 

Remove all packaging from the unit. Retain the packaging. If you dispose of it 

please do so according to local regulations.
The following items are included:

•  The Main Unit

•  The Water Hose (P.N.: K01-08001000001)

•  The Instruction Manual (P.N.: L8DHW10-003)
If items are missing or damaged, please contact Partmaster (UK only).
Tel: 0844 800 3456 for assistance.

      

 PRODUCT OVERVIEW

       CONTINUOUS DRAINAGE

Water can be automatically emptied into a floor drain by attaching the unit with 

a water hose (12mm).
•  Insert the water hose into the drain 

outlet as shown. Lead the hose to a 

suitable drainage facility.

•  Connect the unit to the mains socket and 

continue operation.

       CLOTHES DRYING

When the unit is used to dry your 

clothes, press the HUMIDITY button to 

CLOTHES DRYING mode which is the 

highest dehumidification setting of the 

unit. Put the unit near the wet clothes 

and allow the dry air to blow towards 

the wet clothes.

       CLEANING & MAINTENANCE

Maintenance of your air filter
The air filter located inside the air inlet of the unit collects dust contained in the 

air. The build up of dust reduces the efficiency of the unit. To prevent the dust 

from clogging up the unit always use it with the air filter in place.
Always clean the air filter every 2 weeks. If the unit operates in a dusty 

atmosphere clean the air filter more often.
•  To remove the filter, pull up the plastic lip at the 

bottom of the vents as shown.

•  Clean the air filter with a vacuum cleaner. lf the air 

filter is very dirty, you can wash it in warm water 

(never use hot or soapy water). Make sure that the air 

filter is refitted correctly to the unit. Do not bend the 

filter and ensure it is fitted before operating the unit.

Cleaning the unit
•  Clean the unit by using a damp sponge, and dry it with a clean, soft cloth.

•  Never use alcohol or any product containing solvents.

•  Do not immerse the unit in water.

       BEFORE USE

1. Place on a stable, flat floor. If the floor surface is not even:

•   Vibration and noise will occur.
•   Water may leak from the water tank

2. Make sure the air inlet and air outlet openings are clear and free from blockage.

       OPERATION

1. Connect the unit to the mains socket. The units alarm will sound 3 times.
2. Press the ON/OFF button to turn the unit on. The indicators on the control panel 

will illuminate to show the currently selected functions.

3. Select the desired functions by repeatedly pressing the relevant button.
4. Press the ON/OFF button to turn the unit off.

       OVERHEAT PROTECTION

This unit has an overheat protection device. If the unit overheats, the ALARM 

indicator will illuminate and the unit will shut down automatically.
Unplug the unit from the mains socket. After 5 minutes reconnect the unit to the 

mains socket. Turn the unit on again and continue operation.

       WATER TANK FULL

When the water tank is full, the alarm will sound 10 

times. The WATER FULL indicator will illuminate and 

the unit will automatically stop operating. Turn off the 

unit and remove the water tank. Empty the water and 

then refit the water tank back to the unit. Turn the 

unit on again and continue operation.

The unit must stand upright for at least 2 hours prior to use.

When the unit is turned off, the motor will still keep running for 5-10 

minutes. Do not unplug the unit unless the motor has stopped as this may 

cause damage to the motor.

Do not put the unit directly under wet clothes 

as the water from the clothes must not drip 

down onto the unit. This may jeopardise the 

unit or raise the risk of an electric shock.

When the hose is not being used, 

remove the hose from the drain 

outlet. The hose level must be 

lower than the drain outlet, see 

diagrams shown below.

Front View

Rear View

Control Panel

1

2

3

4

5

6

7

8

9

1

ON/OFF

POWER

TIMER

IONIZER

HUMIDITY

ALARM

ECO
NORMAL
TURBO

40%
50%
60%
CLOTHES

DRYING

1H

ON

2H
4H
8H

WATER FULL

1

2

3

4

5

Air Outlet

2

Water Level Window

3

Control Panel

4

1

Water Tank

5

Mains Cable

6
9

Handle

7

Air Intake

8

Drain Outlet

Water Hose

ON/OFF button: To turn the unit on and off. 

ALARM indicator : 

Illuminates when the unit is overheated.     

WATER FULL indicator : 

Illuminates when the water tank is full or not in  

 

place. 

3

HUMIDITY button:  

4
5

TIMER button: To select the auto shut off function (select from 1/2/4/8 hours.)
IONIZER button: To select the releasing negative ion function.  

40% :

 

Maintain room humidity at 40%. 

50% :

  

Maintain room humidity at 50%.      

60%:

 

Maintain room humidity at 60%.    

CLOTHES DRYING :

 

Continous dehumidification regardless of room  

 

humidity.

2

POWER button:  

ECO :

 

Dehumidification with a low fan speed.     

NORMAL :

 

Dehumidification with a high fan speed.       

TURBO :

 

Dehumidification with the highest fan speed.

       SUITABLE FOR USE IN

• Bedrooms   

 

 

• Studies 

 

• Cellars / Basements    

 

• Kitchens   

 

• Storage rooms 

 

 

• Libraries

• Galleries    

 

 

• Computer rooms

Protects moisture sensitive items, such as :

• Musical instruments    

 

• Cameras   

• Computers
Benefits:

• Prevents clothes and leather products from moulding.

• Dehumidifies flooring and carpets.

• Prevents ceiling and windows from condensation.

• To obtain best results, try to avoid opening and closing windows and doors.

Water 