13
Maintenance
Changing the Internal Light
1. Before carrying out the bulb replacement always
adjust the thermostat control dial to Position 0FF, then
disconnect the mains supply.
2. While holding the lamp cover place coin between lamp
cover lip and internal wall of the refrigerator and twist
the coin.
3. Remove the lamp cover.
4. Remove the old bulb by unscrewing in an
anti-clockwise direction.
5. Replace with a new bulb (10W SES). Please make sure that it is secure in the bulb cover.
6. Refit the light bulb cover and reconnect the unit to the mains supply and switch on.
Care When Handling / Moving Your Unit
Hold the unit around its sides or base when moving it. Under no circumstances should it be lifted by holding the
edges of the top surface.
Servicing
The unit should be serviced by an authorised engineer and only genuine spare parts should be used. Under no
circumstances should you attempt to repair the unit yourself. Repairs carried out by inexperienced persons may
cause injury or serious malfunction. Contact a qualified technician.
Switching Off for Long Periods of Time
When the unit is not in use for a long period of time, disconnect it from the mains supply, empty all food and
clean the appliance, leaving the door ajar to prevent unpleasant smells.
Disposal
Old units still have some residual value. An environmentally friendly method of disposal will ensure that valuable
raw materials can be recovered and used again. The refrigerant used in your unit and insulation materials require
special disposal procedures. Ensure that none of the pipes on the back of the unit are damaged prior to disposal.
Up to date information concerning options of disposing of your old unit and packaging from the new one can be
obtained from your local council office.
When disposing of an old unit break off any old locks or latches and remove the door as a safeguard.