Figure 1

 

 

 

 

 

Before each intervention into the inner parts of the construction of the water heater, it is 
necessary to always disconnect from both sources of AC and DC current! 

Accumulation water heaters with combined heating using  AC and DC current may be used to heat water by 
AC  current  only  from  the  grid,  or  by  DC  current  from  photovoltaic  panels  or  simultaneously,  in  various 
combinations of temperatures set by means of two separate thermostats. LX water heaters are even meant 
for 

pre-heating

 and 

supplementary

 heating of water.  This type of use is suitable as a supplementary system 

for already existing system of water heating for users using a system in which the heater is placed before or 
after the system.  All water heaters of the M+K(W) line are equipped with a tubular heat exchanger, which 
allows them to connect to an external heat source (furnace, fireplace, natural gas heater, and the like).   For 
M+KW  models  that are made only  in  the 200L  version,  the  tubular heat  exchanger  is located  in  the upper 
part of  the heater.  That type of solution enables the  top half to be heated by gas and the bottom half by 
photovoltaic  panels  and  once  the  temperatures  are  in  balance,  then  all  200L  of  the  water  heater  only  by 
photovoltaic  panels.    The

  M+KW

  model  can  also  be  utilised  as  a  source  of  power for floor heating  in  low-

energy and passive homes.  

Summary of Contents for LX ACDC/M+K 100 A

Page 1: ...DC M K 200 A B C LX ACDC M KW 200 A B C MANUFACTURER LOGITEX spol co s r o Ltd portovcov 884 4 SK 02001 P chov Phone no 421 42 4710200 Fax 421 42 4642300 logitex logitex sk Made in Dru stevn z vody Dr...

Page 2: ...C HOT WATER HEATER 10 4 4 DIMENSIONS OF LX ACDC M K 100 A B C LX ACDC M K 125 A B C LX ACDC M K 160 A B C LX ACDC M K 200 A B C 11 5 Operating activity 11 6 Accessories 12 7 Wall mounting 12 8 Plumbi...

Page 3: ...be observed The product s reliability and safety have been verified by tests implemented by EVP Nov Dubnica The manufacturer reserves the right for engineering modification of the product The product...

Page 4: ...ing qualities Voltage 30V 10 and Current 8 3A 5 1 FV panel Photovoltaic panels can be installed at any place with maximum sunshine and south oriented but must not be freely accessible due to the fact...

Page 5: ...ementary system for already existing system of water heating for users using a system in which the heater is placed before or after the system All water heaters of the M K W line are equipped with a t...

Page 6: ...m photovoltaic panels keeps heating the water to the preset temperature on thermostat T2 If the water temperature drops water withdrawal to below 45 C with the sun shining the water is very quickly an...

Page 7: ...n control light signalizes the input of the direct current from the photovoltaic panels If it is on the panels are producing electrical energy Heating water by means of AC current from network is indi...

Page 8: ...hrough its reaction with water it creates an environment that prolongs the lifetime of the tank The design of the anode and the material used comply with the standard EN 12438 A thermometer that trans...

Page 9: ...9 4 TECHNICAL DESCRIPTION 4 1 DIAGRAM OF LX ACDC M K 100 A B C LX ACDC M K 125 A B C LX ACDC M K 160 A B C LX ACDC M K 200 A B C Figure 2 4 2 DIAGRAM OF LX ACDC M KW 200 A B C Figure 3...

Page 10: ...10 4 3 DIMENSIONS OF THE LX ACDC M KW 200 A B C HOT WATER HEATER Figure 4...

Page 11: ...cet hot water valve is opened the water from the water supply conduit pressed out by cold water pressure flows out of the heater Hot water flows out through the top part and water flowing in remains i...

Page 12: ...afety valve with a membrane spring The safety valve must be easily accessible as close to the heater as possible The inlet pipes must have at least the same clearance as the safety valve The safety va...

Page 13: ...afety valve If the pressure in the water piping exceeds 0 6 MPa we recommend installation of a pressure control valve as well The appliance is not designed to be serviced by people including children...

Page 14: ...Connection to electric network shall be executed only after the plumbing has been installed Elements for disconnection from the electric grid must be built into the fixed electric grid distribution t...

Page 15: ...dicator of DC spiral activity TP Heat fuse S3 Indicator of AC spiral activity St1 Contactor for switching on FV heating St2 Contactor for switching between R1 AC Heating element R2 DC Heating element...

Page 16: ...ing system Check proper placement of operating and safety thermostat sensors The sensors in the well must be inserted all the way in first the operating and then the safety thermostat b Open the hot w...

Page 17: ...ting the LX ACDC M KW 200 A B C for floor heating systems for low energy and passive homes Figure 8 Fire fighting regulations for heater installation are defined in relevant standards The heater must...

Page 18: ...rial has been paid for the packaging in which the water heater was delivered The service fee was paid in accordance with Act no 477 2001 Coll as subsequently amended at EKO KOM a s The client number o...

Reviews: