28
6.2 Oil change
Draining the oil:
1. Bring the unloaded forks down to the lowest position.
2. Most of the oil can be drained by loosening the hydraulic hose union in the
bottom of the cylinder. Activate the hydraulic pump by pressure on the switch.
The oil will run out.
3.
Take off the side plates.
4.
Take off the cables of the battery. Remove from the battery box: cables, two
mounting bolts and cable holder and push the battery box to the right.
5. The remaining oil is emptied from the oil tank by sucking up the oil.
6. Place the hydraulic hose again.
7.
Oil is filled in by removing the oil filler cap from the tank.
8. Oil quantity:
The oil level is measured from the upper edge of the tank and downwards
Oil level
SELFR 920 & SELFSR 920
approx. 3 liters
40 mm
SELFR 1200 & SELFSR 1200
approx. 3 liters
40 mm
SELFR 1400 & SELFSR 1400
approx. 3 liters
40 mm
SELFR 1600 & SELFSR 1600
approx. 3 liters
40 mm
SELFR 1910 & SELFSR 1910
approx. 3,5 liters
32 mm
9.
Refit the angular hose nipple and bleed the system (see. 6.3).
6.3 The hydraulic pump and the gear motor
The hydraulic pump has a S3 “periodic intermittent duty” of 10%. This means that
the pump in total is allowed to operate 1 minute for a period of 10 minutes.
NOTE!
If the pump operates more than 10%, the motor will be damaged due to
superheating.
Bleeding the hydraulic system
With a load of 50-100 kg, the forks must be raised and lowered to top and bottom
position 2-3 times.
6.0 Long live the Rotator