Lohberger Heiztechnik
GmbH
Operating Instructions
N29/HB/GB
page 60
Lohberger Heiztechnik GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40
Tel. 0662-450444-0, Fax-DW 9
Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
Deactivate measurement operation:
The measurement operation is deactivated automatically after 600 minutes (10 hrs).
The measurement operation can be deactivated prematurely (see also "OFF" or "ON"):
NOTICE 1: After deactivating the measurement operation, the operation mode is automatically
reactivated that was active before the activation.
E.g.: before the activation, the burner switch was set to "OFF" and the fuel selection was set to
"Only logs" – with activating the measurement operation, the burner switch is set to "ON" and the
fuel selection to "Pellets / Logs".
After deactivation, the burner switch is reset to "OFF" and the fuel selection to "Only logs".
NOTICE 2: The measurement operation can also be deactivated via the burner switch (by changing
it to "OFF"); in this case, the burner switch will not be reset into the initial position (meaning: if it
was set to "ON" before activation it remains now on "OFF").
There is the possibility of overheating if the boiler is operated in the manual
operation for too long. Do not forget to pellet / logs reset as soon as the chimney sweep
measurement was completed.