Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
Documentation on ash-door plate / transport instructions
6
Assembling the components incl. fitting of cables
6.1
Assembly induced draught fan & lambda probe & heat exchange motor
Induced draught fan with seal
Place the seal on the induced draught fan as pictured
(labelling visible) and inter-connect the pieces so that
the holes in the seal and in the mounting plate are
aligned.
R
Induced draught fan
Mount the induced draught fan on the boiler.
Pay attention to the correct positioning when
installing the fan: The taper on the mounting
plate points towards the flue pipe.
Induced draught fan &
Lambda probe fitting
Heat exchange motor fitting
Screw the lambda probe in place above the
induced draught fan and plug in the lambda
probe cable, induced draught fan cable and
the heat exchange motor cable.
Flue pipe
Induced draught fan mounted correctly