7.3
Home screen in detail
7.3.1
Boiler temperature:
Here, the current temperature of the water in the boiler is displayed in °C.
During operation, it ranges between 65 and 85°C. During operation with pellets and logs, the value
ranges typically between 68 and 78°C. (In this temperature range, the boiler emits its full power; if
the boiler temperature exceeds 82°C, the power will be reduced to 50%.)
7.3.2
Fuel selection:
Here, the burner's operation mode is displayed:
Pellet:
The pellet burner starts as soon as the upper buffer temperature has fallen under the starting value
and stops as soon as this temperature exceeds the switching-off value.
7.3.3
Process water temperature:
Here, the current temperature of the process water 1 is displayed.
(if there are several bus modules process water 1, 2 or 3 can be chosen in the special settings menu.)
7.3.4
Outside temperature:
Here, the current outside temperature is shown.
7.3.5
Buffer fill level:
Here, the current fill level of the buffer is displayed in %: Vessel full = Temperature on top and
bottom 75°C at least; Vessel empty: Temperature on top and bottom below 35°C.
7.3.6
Boiler typ:
Here, the boiler type is displayed on which the setting is preset. This setting is preset by the
programme and cannot be changed.
7.3.7
Burner running time:
Here the running time of the last or current burner cycle is displayed. 3:01 = 3 hours, 1 minute. With
the info "Pellet operation start" or after a power failure, this counter is set to 0.
In this state, the counter display is hidden.
7.3.8
Time:
Here, the current time is displayed.
7.3.9
Position burner switch:
Here, the position (ON/OFF) of the burner switch is displayed.
The switch position can be changed by repeated pushing of the button beneath (arrow up).
ON = The burner switch is switched onstarts and stops the pellets burner automatically depending on
the buffer temperature.
OFF= The burner switch is switched off.
ON, flashing = Frost protection triggered; the burner switch was initially set to OFF, due to risk of
frost, it was set to ON automatically. The pellet burner runs until frost risk is averted.