of missentry, it will be corrected automatically.
From „11:30“ to
„13:00“:
This is the second time slot of heating circuit 1 (see description of "first
time slot")
From „17:00“ to
„22:00“:
This is the third time slot of heating circuit 1 (see description "first time
slot").
NOTICE:If the current system time (see main menu "Date/Time") is
outside any time slot and the heating circuit operational mode (see "H-
circ. 1 Operational Mode") is set to “Automatic High/Low”, the heating
circuit runs on "Low temperature".
EXAMPLE: If the time settings are as in the menu frame illustrated
above and the heating circuit operational mode is set to “Automatic
High/Low”, the heating circuit operates as follows:
High temperature from 6:00 to 9:00 o'clock, Low temperature from
9:00 to 11:30 o'clock,
High temperature from 11:30 to 13:00 o'clock, Low temperature
from 13:00 to 17:00 o'clock,
High temperature from 17:00 to 22:00 o'clock, Low temperature
from 22:00 to 6:00 o'clock.
Week:
Via this field, you access the menu frame "H-circ. 1 Week"-
(see "Navigating the menu").
This is an entering assistance – if you want to set the same Timeprog for
every day of the week, you set the Timeprog for one day as requested,
access subsequently "H-circ. 1 Week" and push the button
–
afterwards the timprog of the "example day" is cloned to every day of
the week.
E.g. Mo to Fr 5-22 o'clock, Sa and Su. 8-23 o'clock: Select Monday,
enter timeprog 5-22 o'clock,clone this day's setting to all days (now,
every day has the timeprog 5-22 o'clock) – now, set Saturday and
Sunday separately to 8-23 o'clock
H-circ. 1 Heatcurve
The heatcurve:
The heatcurve is a substantial part of the "weather-compensation": It sets the flowtemp. of the
heating circuit in relation to the respective outside temperature.
3 points of the heatcurve can be set:
Example (factory setting for radiators):
at +21°C the flowsetvalue is set to 36°C,
at 0 °C to 55°C, and
at -15°C to 70°C.
This results in a "curve" that is the basis for the flowtemp.setvalue of the heatingcircuit: