7.2
Menu item „ screed drying “
In general:
If in the basic settings menu the heating system "Floorheating" has been selected at least once, in
the main menu the item "Screed Drying" is displayed. Via this item, the menu frame shown here is
accessible.
Here, all heating circuits set to "ON" and "Floorheating" in the basic settings menu are listed.
In this frame, a fix flow- temperature for each heating circuit can be set in order to dry the screed.
Please follow the instructions of the screed manufacturer.
H-circ.1 Off/On:
If the text selection is switched from "Off" to "On", the corresponding heating circuit heats with the
flow-temperature shown next to "Temp." (e.g. in the picture above, 15°C); heating circuit operation
mode, outside or ambient temperature are of no concern in that case.
During operation, the value "Temp."(= fix flowtemp.setvalue) can be adjusted according to
demand.
As soon as the text selection is set back from "On" to "Off", this function is not active any longer
and the regular heating operation is resumed.
NOTICE 1:
Premise: Burner switch "ON", sufficient fuel supply.
NOTICE 2:
If the drying function is active, this is shown in frame "H-circ. x Monitor" in the status line with the
message: "Screed drying on!"