6. Design of the appliance

6. Design of the appliance

Figure 4

1

2

3

10

11

4

5

8

9

7

6

14

13

17

18

12

16

15

1

sheet-metal panelling black

(only with appliance type „Design sheet-metal 
panelling“)

2

Combustion chamber door

3

Fuel drawer

4

Connection at the top

5

Decorative glass / tile inlay 

(only with appliances of type “Design sheet-
metal panelling”)

6

Combustion chamber door handle

7

Combustion chamber door body

8

Combustion chamber door sealant

9

Combustion chamber door viewing glass

10

Combustion chamber door latch

11

Decorative glass inlay of fuel drawer

12

Fuel drawer runner

13

secondary air slider

14

Combustion chamber lining

15

Combustion chamber grate

16

Combustion chamber door catch

17

stove body combustion chamber door 
latch plate 

18

primary air slider
stainless steel decorative frame

(not shown – only with appliance type 

“Customer-supplied panelling”)

Summary of Contents for THermo Insert DEPENDENT

Page 1: ...THermo Insert Issued January 2012 independent of indoor air DEPENDENT on indoor air Operating Manual with installation instructions GB...

Page 2: ...on 5 4 Important standards guidelines 5 5 Special notes 5 6 Design of the appliance 6 7 Fuels 7 8 Chimney Flue pipe connection 7 9 Air supply for combustion WITH dependence on indoor air open flued ap...

Page 3: ...slowly and first allow the flue gas to escape up the chimney By doing this you prevent the flue gas from entering the room Bear in mind that certain components of the appliance filling door handles et...

Page 4: ...d out on every fireplace and all the connected system components e g chimney etc Please observe the instructions regarding maintenance and cleaning in this operating manual Your chimney sweep will als...

Page 5: ...standards regulations FIRE HAZARD FIRE HAZARD RISK OF BURNS RISK OF BURNS The packaging of your appliances provides good protection against damage in transit Nevertheless damage to the appliance and f...

Page 6: ...al panelling 6 Combustion chamber door handle 7 Combustion chamber door body 8 Combustion chamber door sealant 9 Combustion chamber door viewing glass 10 Combustion chamber door latch 11 Decorative gl...

Page 7: ...e exhaust system must be inspected by the local qualified chimney sweep before starting to use the appliance The exhaust system must be inspected by the local qualified chimney sweep before starting t...

Page 8: ...y slightly pre heated Max length 4 m with 3 bends Negative pressures in the room where the ap pliance is located e g through ventilation sys tems extractor hoods etc may impair the func tioning of the...

Page 9: ...and must be protected against wind The air duct must be at least 100 mm in diameter If rectangular pipes are em ployed an appropriate cross section must be maintained According to the regulations for...

Page 10: ...s ith combustible floors timber flooring synthetic materials fitted carpet etc the use of a floor pad made of safety glass or similar non combustible materi als is recommended According to fire protec...

Page 11: ...ction air casing and the heating appliance must be at least 15 cm The cold room air enters from below via the supply air grille 11 heats up and is fed back at the top through the flue gas grille into...

Page 12: ...p over the fuel results in combustion appropriate for the fuel being used resulting in low pollution emissions Part of the secondary air washes down across the glass front This air wash system ensures...

Page 13: ...s the heating requirements of the room is established by experimenting Guideline values for the fuel quantity and burning time The following Tabe 3 shows the recommended amount of fuel to be added for...

Page 14: ...pliance components grate ash pan ensure they are correctly positioned and function as required and or that there are no leaks Using the vacuum cleaner Allow the appliance to cool down completely and o...

Page 15: ...time Figure 18 To do this swivel the grate using the supplied grate lifter 1 Use the grate lifter to remove the ash pan towards the front 2 3 and empty it then clean the ash chamber Grate If the air...

Page 16: ...o order spare parts Problem Fault Possible cause Solution Smoke escaping during heating up or heating Chimney still cold or stale air in the chimney Light ball of paper in the stove and allow it to bu...

Page 17: ...German standards are complied with Regensburger Norm Stuttgarter Norm and M nchner Verordnung T V Test report number W O 1190 0008 Dimensions installation dimensions Width x height x depth cm 44 x 49...

Page 18: ...nsions appliance connections Dimensions in cm Installation dimensions Design Customer supplied panelling Design Sheet metal panelling 125 114 128 5 52 5 14 3 52 5 109 5 109 5 49 50 5 21 5 22 5 44 7 42...

Page 19: ...Seite 19 Design Sheet metal panelling heat storage block 145 52 5 136 50 5 22 5 51 exhaust gas 12 air intake 10...

Page 20: ...In the event of a repair we will have it carried out correctly and com petently on location or in our works This does not affect the start of the warranty determined by the handover if it is necessar...