User Manual
Installation, Operating and Maintenance Instructions
Stove Alaska 120A / 150A
2.1 STOVE DESCRIPTION
Stove is made primarily of sheet metal and has a closed combustion chamber.
Stove can be placed anywhere in the room (along the wall, in the corner etc.), as long as ground is flat. No
concession is needed for the stove installation.
Increased functionality with simplified regulation
When stove is operating, a layer of ember is formed in combustion chamber, which assures an even burning out of
firewood. By regulating the opening of the air-inlets, one can indirectly control the heat output of the stove.
Lokaterm one-hand regulation (LER)
LER allows easy one-hand regulation of the quantity and distribution of combustion air. If you choose to connect an
external fresh air system LER provides complete tightness and independence of the stove from the room air.
Lokaterm stoves that are equipped with LER are therefore suitable for installation in buildings with forced ventilation.
Lever LER is located under the fire chamber door.
The lever has a central zone for normal operation and two extreme positions:
-
Heating-up position
(fully open air inlet under the ashtray - primary air).
The handle is moved to the left extreme. In the last part of the stroke, it is necessary to slightly raise the lever – on
the step for the activation of the primary air. The lever must be in this position only during the heating-up of the stove -
approximately the first 10 minutes of burning.
-
Normal operation area
(only the air inlet above the door is open - secondary air). This is an area within which the
stove can be continuously used and the power can be regulated. The handle may be located in any position, but not
in the heating-up position.
-
Closed position
of the air inlet (LER lever is moved to the extreme right). The lever is in this position only when the
stove is not in use.
Figure 3: Combustion air regulation lever - LER
Warning
Continuous use of the stove, with a LER handle in heating-up position may overheat the stove, leading to
damage of the exposed parts.
Using the stove at the fully closed air supply (LER lever is moved to the extreme right) is not allowed.
Lokaterm automatic doors (LAV)
Lokaterm automatic doors (LAV) enshure automatically closing and sealing quality throughout the life of the stove.
The air-cooled handle serves to pull the door open. Closing is done automatically with the help of the built-in
mechanism, or by manual applyance of a slight force. Doors have a snap closing mechanism, which snaps the doors
in the totally open position, and starts closing when the snap is released.
Lokaterm clean glass (LCS)
is a system that ensures that you can observe the magic of the burning process
through the clean glass. The hot air enters on the top inner side of the glass and then flows through the glass down,
and thereby deterred the flue gases from the glass.
Lokaterm
page 6
Normal operation area
Heating-up position