Safety First
18
End of Life Treatment
The Waste Electrical and Electronic Equipment recycling (WEEE) Regulations 2006 and the
CE Directive 2002/96/EC require that electrical and electronic equipment must be recycled at
the end of its useful life. This section provides some guidelines.
Emergency Procedures
This section lists the potential emergencies that may be encountered and the associated
procedures.
Quality Assurance
If your business is operating under an approved Quality Management System, all activities
covering the safe operation and maintenance of the metal detector will need to be
incorporated into the system to ensure continued compliance. This section provides some
guidelines on what needs to be considered.
End User Licence Agreement
This section contains details of the End User Licence Agreement for the metal detector
software.
Safety Awareness
Loma metal detectors employ low intensity electromagnetic fields in compliance with current
legislation.
If used in close proximity to an electromagnetic field, the operation of pacemakers, cardiac
defibrillators and other life support devices can be affected.
Wearers of these devices should consult their doctor for advice on avoiding this hazard.
It is essential that all installation, operation and maintenance personnel read this guide before working
on the IQ
3
+ ST Metal Detector and comply with the instructions and information contained herein.
It is also essential that all personnel engaged in activities associated with the installation, operation,
servicing and maintenance of the IQ
3
+ ST Metal Detector have been adequately trained and are
appropriately qualified and experienced to do so.
All personnel should comply with the statutory requirements and regulations, including the provisions
of the Health and Safety at Work Act (UK), other EU relevant legislation, relevant OSHA regulations,
and any amendments that may become legal requirements.
EC Declaration of Conformity
Provided it is installed, operated, serviced and maintained in accordance with the guidelines
contained in this document and the appropriate User Guide, the metal detector addresses the
fundamental safety and health requirements of the following directives:
EC Machinery Directive
2006/42/EC
EC Electromagnetic Compatibility Directive
2004/108/EC
EU-Directive
1935/2004/EC
(Materials for Food Contact)
EU-Directive
2023/2006/EC
(Good manufacturing practice for materials and articles intended
to come into contact with food)
EU-Directive
2011/10/EC
plus amendments
1282/2011/EC
and
1183/2012/EC
(Plastic
Materials and Articles intended to come into contact with food).
A signed and dated EC Declaration of Conformity is provided with each metal detector delivered.
Any modifications made to any part of the metal detector without the prior written agreement
of Loma Systems will invalidate the EC Declaration of Conformity and also product warranty.
Summary of Contents for IQ3+ST
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 212: ...Operating Instructions 202 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 240: ...Maintenance 230 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 244: ...Glossary 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...