Safety First
23
Improper Use
Loma metal detectors are not domestic appliances and should only be used in an industrial
environment.
Loma metal detectors are not suitable for installation or use in explosive or potentially
explosive atmospheres.
Metal detectors must only be installed, operated, serviced and maintained in accordance
with the instructions included in this User Guide.
Electric arc welding must not be carried out on any part of the metal detector unless
authorised by Loma Systems.
All mechanical and electrical protection devices must not be removed or reduced.
The metal detector is not designed for use in hazardous environments where there is a risk
to the health and safety of the operator.
The metal detector must not be operated in very dry environments which can generate
electrostatic charges.
Noise Levels
Generally in an industrial environment some background noise is present due to the operation of
electrical equipment and mechanical movements of machinery such as conveyors and motors.
Loma metal detectors do not emit a level of noise that is hazardous. However, in line with current
legislation, the customer should verify that the overall noise levels within the operating environment
are within defined limits.
End of Life Treatment
In accordance with the Waste Electrical and Electronic Equipment recycling (WEEE) Regulations
2012/19/EU and CE Directive 2002/96/EC, electrical and electronic equipment must be recycled at
the end of its useful life.
The metal detector is considered to be a Large-scale Stationary Industrial Tool (LSIT) as defined in
Article 2 of the WEEE Regulations. Consequently it is the responsibility of the user of the equipment
to ensure the safe disposal of the machine at the end of its useful life.
Emergency Procedures
1
EMERGENCY SHUTDOWN.
This metal detector is fitted with an emergency
‘Stop’
button.
This is mounted on the front panel and is coloured red. In the event of an emergency, which
requires the System to be immediately stopped, press the
‘Stop’
button. See Starting and
Stopping for further details.
2.
DEALING WITH FIRE.
In the unlikely event of fire occurring in an item of equipment
manufactured by Loma Systems, it is important that a fire extinguisher containing the correct
type of extinguishing material is used. Fire on electrical equipment must be extinguished
using a dry powder extinguisher (Blue label).
3.
AUDIBLE WARNINGS.
A conveyor may be fitted with an alarm which operates when a
metallic contaminant is detected in the product. The maximum volume of the alarm is type
dependent and lies in the range of 110 dB(A) to 125 dB(A) at 1 metre.
4.
VISUAL INDICATIONS.
The metal detector may optionally be fitted with indicator lamps,
which operate to show a particular status or in the event of a fault condition. The metal
detector must not be operated unless all such indicators are fully operational. There are also
more detailed fault listings displayed on the operator screen.
Summary of Contents for IQ3+ST
Page 2: ......
Page 36: ...Safety First 26 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 43: ...Installation 33 ...
Page 60: ...Installation 50 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 70: ...About the Metal Detector Range 60 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 172: ......
Page 212: ...Operating Instructions 202 THIS IS PAGE INTENTIONALLY LEFT BLANK ...
Page 240: ...Maintenance 230 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Page 244: ...Glossary 234 THIS PAGE IS INTENTIONALLY LEFT BLANK ...