Operating Instructions
■
P span threshold
This field is only displayed if the PQ span option is enabled in the
Menus > Service >
Configuration > Learn Limits
menu. It is used to set the P span signal threshold (Pmax –
Pmin) to be used during inspection.
■
Q span threshold
This field is only displayed if the PQ span option is enabled in the
Menus > Service >
Configuration > Learn Limits
menu. It is used to set the Q span signal threshold (Qmax –
Qmin) to be used during inspection.
■
Compensation
This is the product compensation set automatically from a Learn process. It cannot be
manually changed.
■
Phase angle
This is the product compensation angle computed from a Learn process. It may be manually
set here if required.
■
Phase
Enabling this option locks the phase angle so that the detector cannot change it during a
Learn process.
■
Head drive
The level of transmitter power is selected here from options of MAX (maximum) full power,
MED (medium) half power and LOW quarter power.
For dry products the level is normally set to MAX.
For difficult products such as metal film or products with a high or non-uniform level of
conductivity, a lower drive setting may achieve a better result.
■
Head
Enabling this option locks the Head drive setting, thus preventing the detector from changing
it during a Full Learn process.
■
Head P gain
The signal level of the P channel (in phase signal) is adjusted here. The adjustment is made
automatically during a Full Learn process based on the product effect on the electromagnetic
field.
Manual adjustment is not recommended unless absolutely necessary. Options of MAX, MED,
LOW and MIN are available for selection.
■
Head Q gain
The signal level of the Q channel (90 degree phase signal) is adjusted here. The adjustment
is made automatically during a Full Learn process based on the product effect on the
electromagnetic field.
Manual adjustment is not recommended unless absolutely necessary. Options of MAX, MED,
LOW and MIN are available for selection.
■
Head RF gain
This is a specialised setting for use with metallised film or very difficult conductive products.
The head RF gain is adjusted through the software by changing the setting in this screen but
may also be adjusted manually through the fitting of links onto the Transmitter Board.
The software adjustment is made automatically during a Full Learn process based on the
product effect on the electromagnetic field.
Manual adjustment is not recommended unless absolutely necessary. Options of MAX, MED,
LOW and MIN are available for selection.
99
Summary of Contents for IQ3
Page 2: ......
Page 10: ......
Page 26: ......
Page 43: ...Installation 33 ...
Page 60: ...Installation THIS PAGE IS INTENTIONALLY LEFT BLANK 50 ...
Page 70: ...About the Metal Detector Range THIS PAGE IS INTENTIONALLY LEFT BLANK 60 ...
Page 74: ...Getting Started IQ3 Dual Line Display Menu Map 64 ...
Page 116: ...Operating Instructions THIS PAGE IS INTENTIONALLY LEFT BLANK 106 ...
Page 140: ...Maintenance THIS PAGE IS INTENTIONALLY LEFT BLANK 130 ...