Operating Instructions
o
Metric systems
CTB = Encoder pulses per revolution x 100 x
π
x d
Where: d = the diameter of the roller to which the encoder is fitted in millimetres.
O
Imperial systems
CTB = Encoder pulses per revolution x
π
x d
Where: d = the diameter of the roller to which the encoder is fitted in inches. The
number of pulses provided directly relates to the transport speed. JP7 on the detector
control board must be set in position 1-2.
■
Log speed prob
Because the detector can only work within a predetermined speed range it is possible for the
belt speed to move outside the limit of reliable operation of the machine. Selecting the Log
speed prob option will generate either speed too slow or speed too fast run errors to advise
operators.
■
DSP type
DSP stands for Digital Signal Processing. The following options are available for selection:
O
Off
The resultant signal is based directly on how much the product signal deviates from the
Learnt product reference. Use this option where there is a high level of environmental
noise.
O
Standard
The resultant signal is produced using a tuned detection filter. This is the standard
method of detection for conveyor and pipeline heads. For reactive product the Rate
option can give enhanced performance.
O
Wide
This detection filter is used where the product speed is not known. For example in free
fall and pharmaceutical applications.
O
Rate
This filter is based on how quickly the field changes. This is the recommended option for
reactive product.
■
Product Limit
You can restrict the number of products that you can add to the system by entering a value,
subject to a maximum of 200.
■
Alarm Output
In some instances, such as when carrying out product testing, you may wish to turn off the
audible alarm. Options are provided to Energise or De-Energise the audible alarm.
■
Lamp Type
Options of Dome and Stack are provided. The IQ3 Metal Detector system is generally
supplied with an LED Lamp Stack so the Stack option should be selected.
80
Summary of Contents for IQ3
Page 2: ......
Page 10: ......
Page 26: ......
Page 43: ...Installation 33 ...
Page 60: ...Installation THIS PAGE IS INTENTIONALLY LEFT BLANK 50 ...
Page 70: ...About the Metal Detector Range THIS PAGE IS INTENTIONALLY LEFT BLANK 60 ...
Page 74: ...Getting Started IQ3 Dual Line Display Menu Map 64 ...
Page 116: ...Operating Instructions THIS PAGE IS INTENTIONALLY LEFT BLANK 106 ...
Page 140: ...Maintenance THIS PAGE IS INTENTIONALLY LEFT BLANK 130 ...