69
Operating Instructions
Original Document
Copyright © Loma Systems
Head I Gain
The signal level of the I channel (in phase signal) is adjusted here. The adjustment is made
automatically during a Full Learn process based on the product effect on the electromagnetic
field.
Manual adjustment is not recommended unless absolutely necessary. Options of MAX, MED,
LOW and MIN are available for selection.
Head Q Gain
The signal level of the Q channel (90 degree phase signal) is adjusted here. The adjustment is
made automatically during a Full Learn process based on the product effect on the
electromagnetic field.
Manual adjustment is not recommended unless absolutely necessary. Options of MAX, MED,
LOW and MIN are available for selection.
Head Gain
Enabling this option locks the Head Gain settings, thus preventing the detector from changing
them during a Full Learn process.