26
Getting Started
Document Number: 814212-2.0-ENG
Original Document
Starting the Machine
To start the machine:-
1.
Ensure that the machine is connected to a suitable power supply. If a pneumatic
reject device is fitted then ensure that it has been connected to a suitable air supply.
2.
Turn the Isolator Switch, located on the left hand side of the machine, in a clockwise
direction. This will switch on the electrical supply to the machine. The machine will
then start to load its software.
The Service / Maintenance screen is displayed, providing information on the
operating status of the machine. For more information see the relevant X
5
Reference
Guide which is available on the
Ensure that all levels are within specification before continuing.
3.
Click OK to close the Service / Maintenance screen and display the
4.
Insert the key into the INTERLOCK KEY lock and turn it anti-clockwise to the ON
position. The key must be in place and turned to the ON position for X-Rays to be
generated.
5.
Select
6.
Select diagnostics
Only users of Access level two and above can access the Diagnostics
screens.
7.
Ensure all the indicators are Green or Grey, If there are any RED flashing boxes then
the system will not reset
8.
Push the green Start/Stop button located on the front of the machine to start the
conveyor. The button will change to
Red
, indicating that the conveyor is running.
9.
A calibration process is now started and the Calibration Required screen is displayed.
Select Yes to start the calibration.
10.
The Starting Inspection screen is displayed.
11.
Select Calibrate. The progress of the calibration process is then shown.
12.
Once the calibration has been completed, the Starting Inspection screen closes and
the
13.
The
red
X-RAYS ON lamp will be lit, indicating that X-Rays are being generated.
The machine is now ready to start inspecting the selected product.