COMPILER TECO/ATL
REG. CODE
1-5302-509
MODEL N°
50778
DATE OF ISSUE
10.06.99
REVISION
00
ENDORSED
DATE
10.06.99
57
FUELLING CIRCUIT
XI
143
141
142
Inspections and adjustments
Float chamber level
The level in the float chamber must be checked with the cover of the
carburetor in a vertical position and with the tongue of the float
slightly touching the ball of the reedle valve.
In these conditions, the distance between the float and the surface of
the cover (with seal) must be 27 ± 0.25 mm (dimension X). Work on
the connection of float 1 if the value is different.
Pick-up pump delivery
Pick-up pump delivery cannot be regulated.
The only thing that can be done is to check the amount of fuel
delivered.
Fill the float chamber of the carburetor with fuel and operate the
throttle control lever (from idling speed to high speed) until the circuit
has been completely supplied and the pump jet delivers in a regular
way.
Comply with the following instructions when testing:
Work the pump about ten successive times, stopping with the throttle
completely open after each cycle. Before beginning the return to
idling stroke, make sure that the pump jet has stopped delivering.
Wait a few seconds in the idling position to allow the pump to make
a complete delivery. After the pump has been operated about ten
times, delivery, i.e. the quantity of fuel collected in the test tube, must
be between 8 and 12 cc.
Positive opening
Fully pull out the starter lever and keep it in this position by means of
an elastic band between the lever and the sheath support. The
throttle opening must be 0.65 to 0.75 mm (dimension Y) in these
conditions.
Dimension Y must be measured from the side of the progressive
outlet holes.
If the primary throttle opening fails to correspond to the prescribed
value, modify the position of the adjuster screw (1) and then lock it in
place with the check nut (2).
Partial air powered opening of the ignition throttle
After having fully pulled out the starter, the choke throttle opens
leaving a 4 ± 0.25 mm space (dimension Z) while the vacuum acts
after the primary throttle (simulate the condition by lowering the air
control lever). Measure dimension Z as indicated in the figure.
If choke throttle opening fails to correspond to the prescribed value, it
can be modified by means of adjuster screw (1).