The Santorini Flame Gas Patio heater is supplied 
for  use  outdoors  or  in  amply  ventilated  areas.  
An amply ventilated area must have a minimum 
of 25% of the wall surface area open. 

 

Safety information 

 

Read the instructions before installation 
and use. 

 

The use of this appliance in enclosed 
areas can be dangerous and is 
PROHIBITED. 

 

There must be a minimum clearance 
from combustible surfaces of at least 2m 

 

Use only the type of gas and the type of 
cylinder specified by the 
manufacturer/supplied by London Cool  

 

Do not move the appliance when in 
operation. 

 

Shut off the valve at the gas cylinder or the 
regulator before moving the appliance. 

 

The heat exchange tube must be lowered 
down to position during transportation 

 

The heater cannot be used when the heat 
exchange tube is retracted into cylinder 
compartment. 

 

Do not obstruct the ventilation holes of the 
cylinder housing. 

 

This appliance is not fitted with 

“Atmosphere sensing device”.

 

 

In case of strong winds, particular care must 
be taken that the appliance does not tilt.   

 

Lighting Procedure 

These instructions must be followed to ensure 
your safety. 
 
1.

 

Turn the control knob OFF. Slowly open the 
gas cylinder valve.  

 
2.

 

Push in and turn control knob anti-
clockwise to IGNITE. 

3.

 

Keep control knob depressed for up to 30 
seconds until pilot is lit. 

4.

 

If pilot does not light, turn control knob 
to OFF and wait 5 minutes between 
ignition attempts for gas to dissipate.  

NOTE: It is possible to 
light the appliance using 
a long match by lighting 
the burner through the 
ignition hole provided. 

5.

 

When the pilot is lit, keep 
knob pressed for up to 20 seconds, then 
release it (first ignition generally takes 
longer because the gas circuit is full of air). 

 
6.

 

If the pilot does not stay lit, repeat steps 1-
3, waiting 5 minutes before attempting to 
relight. 

 
7.

 

Turn knob to LOW position then turn knob 
from LOW to HIGH position and back, to 
check flame stability. 

 
8.

 

Adjust the heat input by turning the knob 
from the LOW position, to HIGH as 
required.   

9.

 

If the flame accidentally goes out (due to 
wind or other reasons), a Flame Safely 
Device (FSD) will automatically shut off the 
gas supply within 90 seconds. 

Reviews: