Santorini Flame Gas Patio heater
–
Operating instructions
The Santorini Flame Gas Patio heater is supplied
for use outdoors or in amply ventilated areas.
An amply ventilated area must have a minimum
of 25% of the wall surface area open.
Safety information
•
Read the instructions before installation
and use.
•
The use of this appliance in enclosed
areas can be dangerous and is
PROHIBITED.
•
There must be a minimum clearance
from combustible surfaces of at least 2m
•
Use only the type of gas and the type of
cylinder specified by the
manufacturer/supplied by London Cool
•
Do not move the appliance when in
operation.
•
Shut off the valve at the gas cylinder or the
regulator before moving the appliance.
•
The heat exchange tube must be lowered
down to position during transportation
•
The heater cannot be used when the heat
exchange tube is retracted into cylinder
compartment.
•
Do not obstruct the ventilation holes of the
cylinder housing.
•
This appliance is not fitted with
“Atmosphere sensing device”.
•
In case of strong winds, particular care must
be taken that the appliance does not tilt.
Lighting Procedure
These instructions must be followed to ensure
your safety.
1.
Turn the control knob OFF. Slowly open the
gas cylinder valve.
2.
Push in and turn control knob anti-
clockwise to IGNITE.
3.
Keep control knob depressed for up to 30
seconds until pilot is lit.
4.
If pilot does not light, turn control knob
to OFF and wait 5 minutes between
ignition attempts for gas to dissipate.
NOTE: It is possible to
light the appliance using
a long match by lighting
the burner through the
ignition hole provided.
5.
When the pilot is lit, keep
knob pressed for up to 20 seconds, then
release it (first ignition generally takes
longer because the gas circuit is full of air).
6.
If the pilot does not stay lit, repeat steps 1-
3, waiting 5 minutes before attempting to
relight.
7.
Turn knob to LOW position then turn knob
from LOW to HIGH position and back, to
check flame stability.
8.
Adjust the heat input by turning the knob
from the LOW position, to HIGH as
required.
9.
If the flame accidentally goes out (due to
wind or other reasons), a Flame Safely
Device (FSD) will automatically shut off the
gas supply within 90 seconds.