background image

IIn

ns

stta

alllla

attiio

on

n,,  W

Wa

arrrra

an

ntty

y  a

an

nd

d  S

Se

errv

viic

ce

e  IIn

nffo

orrm

ma

attiio

on

n

www.pager.net

T74

USB

FCC

 ID: M

74T

740

0

USB

Rec

eive

Tran

sm

it

Pow

er

9VAC

800.4

37.4

996

www

.pag

er.ne

t

T

74

USB

Paging System Transmitter

U S E R   M A N U A L

Long Range Systems UK Ltd | Link House | Leek Road | Milton | Stoke on Trent | Staffordshire | ST2 7AH | 01782 537000
www.lrspagers.co.uk | www.pagers.co | www.hospitalpagers.co.uk

Summary of Contents for T74USB

Page 1: ... on n www pager net T74USB FCC ID M74T7400 USB Receive Transmit Power 9VAC 8 0 0 4 3 7 4 9 9 6 w w w p a g e r n e t T74USB Paging System Transmitter USER MANUAL Long Range Systems UK Ltd Link House Leek Road Milton Stoke on Trent Staffordshire ST2 7AH 01782 537000 www lrspagers co uk www pagers co www hospitalpagers co uk ...

Page 2: ...bleOfContents Installation and Setup 2 Set Restaurant ID 3 Repeat Delay 4 High Power Setting 4 Frequency 5 RF Baud Rate 5 Service Questions and Answers 6 Warranty 7 Long Range Systems 1 T74USB User Manual ...

Page 3: ...nal on the host computer 5 Assign a Name for the new connection 6 Select the COM Port coming from the USB cable 7 Use the following settings Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None 8 Type ECHO1 and press ENTER This echo function will allow you to see what is being typed 9 You are now ready to use the interface Note At any time use the STAT command to view any cha...

Page 4: ...D type RID x and press ENTER twice X is the Restaurant ID Example To set an ID of 2 type RID 2 and press ENTER twice Long Range Systems 3 T74USB User Manual Example Restaurant ID to 2 HyperTerminal Output Showing ID as 2 Type STAT and press ENTER Status View Showing Restaurant ID as 2 ...

Page 5: ...er Setting type HWPR x and press ENTER twice X is the Power Setting a value of 1 to 4 Example To set a Power Setting of 3 type HWPR 3 and press ENTER twice Long Range Systems 4 T74USB User Manual Example Repeat Delay ON Status View Showing Repeat Delay ON Example High Power Set to 1 HyperTerminal Output Showing High Power Set to 1 Status View Showing High Power Set to 1 ...

Page 6: ... change the Baud Rate type RFBAUD x and press ENTER twice X is the value of the Baud Rate at 512 1200 or 2400 The default Baud Rate of Alpha Numeric Pagers is 1200 If the rate on the transmitter is changed the rate of the Alpha Numeric Pagers will also need to be changed Example of Set Frequency PLL to 37420 467 750 MHz HyperTerminal Output Showing Frequency PLL Set to 37420 467 750 MHz Status Vie...

Page 7: ...g supplies call Long Range Systems at 800 437 4996 Monday through Friday 8 30 am to 5 00 pm Central Time For weekend or night emergencies Long Range Systems has 24 7 live technical support available Please keep in mind that options are limited over the weekend Long Range Systems 6 T74USB User Manual ...

Page 8: ...cular purpose nor does LRS Inc assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability including without limitation consequential or incidental damages Typical parameters that may be provided in LRS Inc data sheets and or specifications can and do vary in different applications and actual performance may vary over time A...