background image

Table of Contents

Introduction
Operation Panel
Basic Operation

Menu Frame Work
Multi-channel Running Interface
Multi-channel Functions Setting

Single Channel Running Interface
Single Channel Functions Setting

Acceptable Drive Units and Syringes
Syringe Loading
External Control Function
Maintenance
Warranty
Technical Specifications

Start/Stop Key
Fast Forward Key
Fast Reverse Key
Rotary Coded Switch

Channels Switch Key
Exit Key

Select Drive Unit
Select Copy Parameters
Set Delay Time
Controller I.D.

Working Mode Selection
Syringe Select
Dispense Parameters Setting
Calibration
Display Select

Important Information:

Warning:

Please read operating manual carefully before operation.

Over-push or over-draw the syringe may result in the fluid
sprayed. Use appropriate measures to protect operator
and equipment. Be careful during operation.

When the fluid sprays out on the drive unit please shut
down the power supply immediately and clean the drive
unit, then turn on the power supply.

If a trouble happens please contact us or our dealer. Don't
repair the equipment by yourself.

Be careful when inserting or extracting the connection
wire between controller and drive unit to prevent the plug
from damaging.

If the power line or the plug are worn or damaged please
pull out the plug.

Please shut down the power supply before connecting the
external control equipment.

SYRINGE PUMP OPERATING MANUAL

1

2

2

2

4

4

6

8

8

9

1 1

1 5

2

2

2

2

2

3

4

1 6

1 7

1 9

2 1

5

6

5

2 1

2 1

2 2

Summary of Contents for TS-1A/L0107-1A

Page 1: ...ease read operating manual carefully before operation Over push or over draw the syringe may result in the fluid sprayed Use appropriate measures to protect operator and equipment Be careful during op...

Page 2: ...Key to start or stop the pump In multi channel working mode to pause the running state the pump will prompt if continue the current working state Fast Forward Key In multi channel working mode pressi...

Page 3: ...me 60sec Act 50 00 L Display Select Volume Speed Flow Multi channel Running Interface Switch on the pump First initializing and then display the running interface a Enabling symbol Symbol of enabling...

Page 4: ...ect if save the change Set Delay Time Set delay time to start each drive unit in turn Time units are sec min and hour Time numerical value is from 0 1 to 999 9 The setting method is as below Turn the...

Page 5: ...unning Interface SYRINGE PUMP OPERATING MANUAL SYRINGE PUMP OPERATING MANUAL Press the RCS Press the Exit Key Press the Exit Key Press the RCS Press the Exit Key Press the RCS Press the RCS Select Yes...

Page 6: ...the Syringe If the syringe used is not listed in the menu the inner diameter of the syringe needs to be measured and entered 0 01 mm 40 mm The pump can save 4 inner diameters of the syringes Please se...

Page 7: ...ing Select No not to save the setting Select Cancel to return to previous menu and keep on selecting Note When the one time dispensing volume or the total dispensing volume multiply one time dispensin...

Page 8: ...selecting Turn the to select if save the parameter RCS Note When the pump can t withdrawal the setting volume in the setting time the running interface will display W speed Overflow see below Please...

Page 9: ...tion volume There are 10 50 and 80 of the syringe volume available When selecting the user defined syringe the default calibration volume is 50 of the syringe volume Please see page 9 Syringe Select t...

Page 10: ...cation Flow Rate L min Glass Syringe SYRINGE PUMP OPERATING MANUAL SYRINGE PUMP OPERATING MANUAL 10 25 50 100 250 500 1000 1 318nL 13 18 L 3 320nL 33 20 L 6 610nL 66 10 L 13 282nL 132 82 L 32 96nL 329...

Page 11: ...htening knobs according to t h e a r r o w h e a d directions to fix the glass syringe 2 See above drawing to load the glass syringe Lift up the p r e s s k n o b a n d rotate the press knob according...

Page 12: ...f them Delaying Startup Delaying startup time of each channel can be controlled separately Memory Function Select resume operation or remain stopped when power returns after an interruption Block Prot...

Page 13: ...ight 3 Kg IP Rating IP41 23 24 TS 1A L0107 1A TS 2A L0107 2A Specifications TS 1B W0109 1B Specifications Max Infusion Distance 70 mm Acceptable Glass Syringe 5 L 1000 L Linear Speed 7 94 m min 79 4 m...

Page 14: ...ecision Pump Co Ltd SYRINGE PUMP OPERATING MANUAL Baoding Longer Precision Pump Co Ltd ADD Building A Chuangye Center Baoding National High Tech Industrial Development Zone Baoding Hebei China 071051...

Reviews: