66
3.9.1 INSTRUMENT ASSEMBLY
1. Engine water temperature
gauge
2. Work hour meter
3. Torque converter oil
temperature gauge
4. Voltmeter
5. Engine oil pressure gauge
6. Braking air pressure gauge
7. Gearbox oil pressure gauge
Monitoring instruments
1. Engine water temperature gauge -
indicate the temperature of the cooling water of
the engine. The indicating range: 60
℃
~120
℃
, (40-120
℃
); the normal working range is
40
℃
~100
℃
. When the temperature of engine’s cooling water is above 100
℃
, the
combination alarm indicating lamp lights up.
When the pointer of the engine water temperature gauge points to the red scale
alarm range, please park the loader in a place safe and suitable for repair work and
shut down the engine. Check the fan and belt of engine, and the water level of water
tank. Do not operate or travel the loader until the failure has been removed. Note:
when checking the fan and belt of the engine as well as the water level of water tank,
please be well prepared for high temperature protection in order to avoid high
temperature scorching.
2.
Work hour meter -
Indicate work time of loader by hours. Indicating range: 0~9999.99
hours. The work hour meter begins to time when the engine is started with electric lock.
3.
Torque converter oil temperature gauge
– indicate the oil temperature of gearbox.
The indicating range is 40~140
℃
and the normal working range is between 40
℃
and
120
℃
. When the temperature of engine’s cooling water is above 100
℃
, the combination
1
3
4
5
6
7
2
Warning