background image

10

6.4 Safety Regulations

6.3 Charging the battery

6.1 Capacity

6.2 Operating and Storing

The battery has a capacity of 12 Ah and is supplied in a charged status. A fully-

charged battery can generate more than 100 fog emissions of 4-5 seconds. The
permanent fogging time amounts to 10 minutes.

When used correctly, the battery holds its capacity for several years and/or some

hundred charge/discharge cycles.

Lead-gel batteries are a very robust bank of capacitors which need little care

and maintenance. However, their working life can be shortened rapidly by storing
them when discharged.

Caution

: Do not store a discharged battery! As a result, it can lose a large part

of its capacity after two weeks!

For charging the battery please use the supplied automatic charger. A discharged

battery can be charged within 10 - 12 hours.

If the battery is in charge, the LED at the charger lights red. If the battery is

fully charged, the LED lights green.

6. The battery pack

• The supplied battery can supply high discharging currents. Therefore:

– Never short-circuit the battery.
– Never change the cable sizes.

• Positioning of the battery

– Make sure the battery is not placed near sources of heat,
– Should you place your battery near a source of heat, the performance of the
battery will decrease the more the temperature rises.

• Using the battery in closed units

– Don‘t use the battery in completely sealed casings or units.
– To prevent a blast of hydrogen leaking from the battery, the casings must be
ventilated.

• Dismantling the battery

– Don‘t dismantle batteries as they do contain electrolytes which may damage
clothing or hurt the skin. If the electrolyte comes in contact with skin or eyes,
immediately rinse with water or consult a doctor.

Summary of Contents for Power-Tiny

Page 1: ...1 Power Tiny a Look Solutions product Operating manual...

Page 2: ...ank 250 ml 1 charger 1 bottle of fluid 250 ml When the order includes a radio remote the following items are supplied additionally 1 receiver with 3 pin XLR plug 1 radio remote 1 manual Radio remote c...

Page 3: ...5 5 Status Display of the Battery Sleep mode 5 6 Changing the battery pack 5 7 Wiring of the connector 6 The battery pack 9 6 1 Capacity 6 2 Operating and Storing 6 3 Charging the Battery 6 4 Safety I...

Page 4: ...er Tiny only heats when fog is actually needed Because of the sleep mode the machine uses only 1 5 milliamperes in idle status and consequently it may remain connected to the the battery for several h...

Page 5: ...e the fog you require and destroy your fog generator Do not swallow the fog fluid Keep it away from children In case of eye contact rinse with a lot of water Consult a doctor should you have accidenta...

Page 6: ...screw 8 Quick connector for fluid tube 9 Fluid tank Adjusting knob LED Battery status display Socket for battery plug 3pin XLR socket 10 11 12 13 1 Start button 2 Fog nozzle 3 Socket for charger 4 Ba...

Page 7: ...o the fog generator no condensed fluid runs into the apparatus no objects jut out into the fog nozzle 2 1 Pour the TINY FLUID into the fluid bottle and firmly lock the bottle Plug the connecting spout...

Page 8: ...o remote A radio remote is available as an option It will be delivered with a 3pin XLR plug a Connect the receiver of the radio remote to the machine using the 3pin XLR socket 12 on the back of the ma...

Page 9: ...e machine press the startbutton 1 3pin XLR analog Pin 1 Ground Pin 2 0 10 V DC in Pin 3 12 V DC out max 50 mA 5 6 Changing the battery pack The battery pack 4 can be changed on site for example if one...

Page 10: ...ic charger A discharged battery can be charged within 10 12 hours If the battery is in charge the LED at the charger lights red If the battery is fully charged the LED lights green 6 The battery pack...

Page 11: ...een lighting LED shows that the battery is fully charged Disconnect the charger from the socket Disconnect the battery from the charger Avoid short circuits Do not short circuit the Speakon cable This...

Page 12: ...specially in the case of old batteries 2 Protect the unit against rain 3 Use the charger exclusively for charging the Power Tiny battery 7 3 Technical Data Model MPP 15 or similar Input voltage 90 240...

Page 13: ...zer is clogged or broken 8 1 2 The yellow LED lights permanently if 8 2 Care and Maintenance To ensure perfect performance of the Power Tiny you should consider the following notes Make sure the fluid...

Page 14: ...capacity 250 ml Fluid consumption 10 ml min with continuous output Continuous output with battery 10 min Temperature control microprocessor Control start button radio remote option XLR remote 0 10 V a...

Page 15: ...vices if any repairs or adjustments are done to the units by unauthorized persons and or if spare parts are used which are not approved by us The right of guarantee service is also lost if fluids othe...

Page 16: ...16 a Look Solutions product...

Reviews: