TO ASSEMBLE:
THE #5-H LOCOLOC
®
HYDRAULIC
PRESS AND PUMP HAS BEEN
SHIPPED IN TWO CRATES.
CRATE #1: HYDRAULIC PRESS
CRATE #2: TABLE AND PUMP
1. After removing press and pump from
the inside of table, turn table upright.
3. Slide pump under table to rear of unit with
pressure gauge facing forward as you look
at front of press.
4. Pass hydraulic hose (marked “gauge”
and “other hose”) through the back of the
mounting table.
2. Place press on table, lining up four
holes on press with four small holes on
table. Secure press to table with the
included bolts and nuts (FIGURE 1).
FIGURE 2
www.loosnaples.com
Toll Free: 800-321-LOOS (5667)
1
FIGURE 1
(4) #5-79HS
1/2 - 20” x 11/2” Hex Bolts
(8) #5-81HS
1/2” Flat Washers
(4) #5-77HS
1/2” Lock Washers
(4) #5-80HS
1/2” Nuts
TO INSTALL DIE SET:
Remove four screws on right side of the upper
and lower dies, then slide the dies out.
To install, place new dies in die shoe, lining up
screw holes with die shoe.
DO NOT OPERATE MACHINE WITH DIES
REMOVED FROM DIE SHOE.
This will damage the die shoe and may be
hazardous
to your safety.
FIGURE 3
To re-adjust die set opening for swaging
different cable sizes:
1. Turn the pump unit on.
2. Loosen the 3/8” x 16” allen head bolt that
secures the ram return micro switch bracket,
and pull upwards. The die shoe will move up
until the micro switch is depressed (FIGURE
4).
3.
FOR OPTIMUM SAFETY, GAP SHOULD
ONLY BE SLIGHTLY LARGER THAN THE
DIAMETER OF CABLE FITTING BEING
SWAGED.
4.
To set the die set lower, make sure the pump
unit is off. Using the 3/4” nut on the back of
the die shoe, turn the adjustable nut clockwise
on the die shoe, and die will move down.
Keep turning until the desired gap is between
the die set (FIGURE 5).