5. Loosen the 3/8” X 16” allen head bolt, 

this secures the ram return micro switch 

bracket. Push down the bracket until you 

hear a faint “click” from the switch.

6.  Tighten the allen head bolt back down 

to hold the micro switch in place. The 

wheel of the micro switch should be 

resting on the small aluminum plate that 

is connected to the die shoe.

FIGURE 5

TO CHECK 

HYDRAULIC OIL 

LEVEL: 

To check hydraulic oil level, remove cap. Oil level 

should be approx. 2 inches below the frame.

To add hydraulic oil remove cap (Figure 6) 

and fill hydraulic oil.

(Use only Enerpac HF-101 hydraulic oil - 

part #4-54HS)

FIGURE 6

BEFORE OPERATING:

1. Re-check hydraulic hoses to ensure they are 

    connected to the correct ports and tightened

    all the way.

2. Make sure the ram return micro switch is set

   correctly. When the die set is open and the  

ram is in the returned position, the Ram 

Return Micro Switch must be set in the “off” 

or “clicked up” position. If the Micro Switch is 

not set correctly, the ram may continue in the 

retract  mode and damage the unit. 

www.loosnaples.com

Toll Free: 800-321-LOOS (5667)

2

(continued on next page...)

Summary of Contents for LOCOLOC 5-H

Page 1: ... 5 H HYDRAULIC SWAGER Locoloc Swaging Tools ...

Page 2: ...DIE SET Remove four screws on right side of the upper and lower dies then slide the dies out To install place new dies in die shoe lining up screw holes with die shoe DO NOT OPERATE MACHINE WITH DIES REMOVED FROM DIE SHOE This will damage the die shoe and may be hazardous to your safety FIGURE 3 To re adjust die set opening for swaging different cable sizes 1 Turn the pump unit on 2 Loosen the 3 8...

Page 3: ... approx 2 inches below the frame To add hydraulic oil remove cap Figure 6 and fill hydraulic oil Use only Enerpac HF 101 hydraulic oil part 4 54HS FIGURE 6 BEFORE OPERATING 1 Re check hydraulic hoses to ensure they are connected to the correct ports and tightened all the way 2 Make sure the ram return micro switch is set correctly When the die set is open and the ram is in the returned position th...

Page 4: ...hich if ignored can be dangerous All fittings hoses gauges etc must be proven for 10 000 PSI 60 000 PSF operation Use only Enerpac hydraulic oil Most hydraulic oils are designed for low PSI systems TO SET PRESSURE Always make sure the die set is in the die shoe before turning the unit on 1 Plug the machine into a 120 volt 60Hz outlet The LCD display backlight will be on and in the auto mode Ram is...

Page 5: ...r oval and stop sleeves 2 500 lbs 1 8 Dies 5 32 Aluminum oval sleeves 2 700 lbs 5 32 Dies 5 32 Aluminum stop sleeves 2 700 lbs 1 8 Dies 5 32 Copper oval sleeves 3 000 lbs 5 32 Dies 5 32 Copper stop sleeves 3 000 lbs 1 8 Dies 3 16 Aluminum oval sleeves 4 000 lbs 3 16 Dies 3 16 Aluminum stop sleeves 4 000 lbs 1 8 Dies 3 16 Copper oval sleeves 4 500 lbs 3 16 Dies 3 16 Copper stop sleeves 4 500 lbs 1 ...

Page 6: ...www loosnaples com Toll Free 800 321 LOOS 5667 5 Pressure Gauge Foot Switch Pump Unit ...

Page 7: ...www loosnaples com Toll Free 800 321 LOOS 5667 6 ...

Page 8: ...104 USA Telephone 239 643 LOOS 5667 1 800 321 LOOS 5667 Fax 239 643 4558 E Mail info loosnaples com Website www loosnaples com Specialists in Wire Rope Hardware Tools Rev 9 19 2018 INST 32 HOW TO VIDEO https www youtube com watch v 0n0HDZ6yWNc ...

Reviews: