Installation
(for qualified installers only)
19
© Travis Industries
4101110
100-01262_000
Top Vent Configuration with Vertical Termination
•
Use 6-5/8” Diameter Vent
•
Horizontal sections require a ¼” (6mm) rise every 12” (305mm) of travel.
•
A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a
horizontal elbow (see illustration).
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
and diffuser position. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor
position may vary slightly, especially when the termination is near a demarcation line.
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
25 feet (7.5m)
30 feet (9m)
40' max (12m)
5 feet (1.5m)
0 feet
0 feet
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
25 feet (7.5m)
30 feet (9m)
40' max (12m)
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
24 ' max (7.3m)
0 feet
5 feet (1.5m)
10 feet (3m)
15 feet (4.5m)
20 feet (6m)
24 ' max (7.3m)
35 feet (10.5m)
35 feet (10.5m)
0 feet
Exhaust Restrictor Position #4
Diffuser Open (stock)
Exhaust Restrictor Position #3
Diffuser Closed
Exhaust Restrictor Position #2
Diffuser Closed
Exhaust Restrictor Removed
Diffuser Closed
Horizontal elbows are elbows placed between
two horizontal sections of pipe. One 45° or 90°
horizontal elbow is allowed for this configuration.
Horizontal Elbow