Safety
Label
37
© Travis Industries
4101110
100-01262_000
Safety Label
The safety (listing) label is attached under the stove. A copy is shown below.
IAPMO-R&T
OCEANA
Gas Mark
TM
GMK10053
Cypress GS (Au)
V
e
nted Gas
Fireplace Heater
T
e
sted to the combustion performance and construction requirements of
AS-4553-2008 Gas space heating appliances.
The vented gas fireplace is equipped from the factory only for use with Natural Gas. For conversion to LP
(Propane) use kit
supplied by the manufacturer
. This appliance must be installed in accordance with all local codes. This appliance is only for u
se
with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured
(mobile) home where not prohibited by local codes. See owner
’s
manual for details. This appliance is not convertible for use
with other gases, unless a certified kit supplied by the manufacturer is used. See owner
’s
manual for information on making
these changes. This appliance uses a millivolt type control system consisting of a gas control valve/regulator
, a standing pilo
t
burner assembly
, a thermopile, a thermocouple, a piezo igniter
, and the ON/OFF switch.
All exhaust gases must be vented
outside the structure of the living-area. Combustion air is drawn from outside the living-area structure.
This appliance is a V
e
nted Gas Fireplace Heater
. Not for use with Solid Fuel.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to
the owner
’s information manual provided with this appliance. For assistance or additional information consult a qualified
installer
, service agency or the gas supplier
.
W
ARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result in
cabon monoxide (CO) poisoning and possible death.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at
least annually by a qualified service person. More frequent cleaning may be required where excessive lint from material like
carpeting and bedding is present. The control compartment, the burner compartment and all circulating air passageways of the
appliance must be kept clean and clear at all times. This appliance must be properly connected to a venting system in
accordance with the manufacturer
’s
installation instructions.
This vented gas fireplace heater is not for use with air filters.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or
clothing ignition.
Y
oung children should be carefully supervised at all times when they are in the same room as the appliance.
Use direct vent systems listed in owner
’s
manual to vent this appliance to the exterior
.
MINIMUM CLEARANCES T
O
COMBUSTIBLES
Stove T
o
p to Sidewall
Stove T
o
p to Backwall
Stove T
o
p to Cornerwall
Glass Front of Unit
254 mm
127 mm
127 mm
915 mm
Alcove Min. Height
Alcove Max. Depth
Alcove Min. W
idth
1220 mm
915 mm
1274 mm
F
AN TYPE VENTED CIRCULA
T
OR
Blower Electrical Rating: 240V
., 1.5
Amps, 50 Hz
Minimum Inlet Pressure (kPa)
Maximum Inlet Pressure (kPa)
Manifold Pressure on “HI” (kPa)
L.P
.
2.74
3.24
2.74
N.G.
1.37
1.74
.87
Input Rate on “HI” (MJ/h)
Input Rate on “LO” (MJ/h)
Main Burner Orifice (DMS)
L.P
.
42.2
7.8
57,53
N.G.
42.2
10.5
49,43
This appliance is equipped for installation 0-610 m. For altitudes above 600m, the vent configuration, orifice, or
combination of both may need to be changed. See owner
’s manual for information on making these changes.
2012
2013
201
1
Feb.
Mar
.
Jan.
May
Jun.
Apr
.
Aug.
Sep.
Jul.
Nov
.
Dec.
Oct.
MANUF
ACTURE DA
TE:
4800 Harbour Pointe Blvd. SW
Mukilteo, W
A
98275
Manufactured by:
D
istributed by:
www
.lopi.com.au
Dragon Wholesaling Pty
. Ltd.
Unit 2, 16 Lexington Drive
Bella V
ista NSW 2153
Australia
0954