Installation
(for qualified installers only)
27
© Travis Industries
4160713
100-01442
5. Install the logs (see page 30).
6. Replace the glass.
7. Start the heater.
8. Leak test all gas joints.
9. Check the air shutter following the directions below.
Air Shutter Adjustment
Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
10. Turn the flame adjust knob to its highest position - the flames should not contact the top of the firebox. Check the flame on low
position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer for
a remedy.
11. Give this manual to the home owner for future reference and fully explain operation of this heater.
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are too tall or sooty on the
ends, open the air shutter.
Not Enough Air
If the flames are all blue and
short, close the air shutter.
Too Much Air
Swing the control cover down to
access the air shutters.
Front Burner Air Shutter Control
(RED)
Left = Less Air
Right = More Air
Rear Burner Air Shutter Control
(GOLD)
Left = Less Air
Right = More Air