Zero Clearance Box
Flush Wood Medium, Flush Wood Large Hybrid-Fyre™
Lopi DVL, DVS GS2, Radiant Plus Large
Dragon Wholesaling Pty Ltd | 2/16 Lexington Drive, Bella Vista NSW 2153 | Phone. (02) 8824 9122 Fax. (02) 8824 6487
Zero Clearance Box Assembly Details
NOTE 1:
(Wood Firebox Installation Only)
There is a different starter section provided for the
Medium Flush Wood and Large Hybrid-Fyre™ models.
Please use the correct starter for the model being
installed.
The Flush Wood Large Hybrid-Fyre™ Starter must be
secured to the top of the firebox and
sealed around
using a fireplace cement as per installation manual.
NOTE 2:
Use plastic insulating cover where the fan power cable passes through
the inner and outer panels
NOTE 3:
(Wood Firebox Installation Only)
A t
riple skin flue must be installed from zero clearance box as per Australian Standards.
A 25mm clearance from the outer 10” casing to any combustible material must be
maintained.
Please see heater owners manual for other clearances and more information.
* Images for illustration purposes only, some details may change
5
The Flush Wood Medium Starter needs to be secured to
the flue collar, however, it is not required to be sealed.
It has been designed with a check out for the bypass rod
at the front and to rest on the tab inside the flue spigot on
the left.
Medium Starter
Large Hybrid-Fyre Starter