Additional functions
- 153 -
02.20
909.2079.9-03
A52
LED F2
Lit continuously (max. 5 secs.) when secondary para-
meter is activated.
Flashes 2x when saving the secondary parameter or
the secondary parameter value.
A53
F2 button
Used to activate the secondary parameter selection
(press for 2 secs).
Used to save the selected secondary parameter (press
for 2 secs).
Used to recall the saved secondary parameter (press
briefly).
2
Main parameters
Depending on the selected welding method
and combined current source control panel,
various main parameters are available/may be
set.
The value of the following main parameters is displayed in
the left-hand 7-segment display A4.
–
Wire feed speed A37
–
Welding current A36
–
Material thickness A35
Â
Select the desired value with the control knob A41.
The value of the following main parameters is displayed in
the right-hand 7-segment display A12.
–
Welding voltage/arc length in V A19
–
Arc length in % A20
Â
Select the desired value with the control knob A44.
3
Assigning function buttons
The control panel offers the option of assigning
any two secondary parameters to the buttons
F1 and F2.
Assigning buttons
Â
Press the button to be assigned, either F1 A50 or F2 A53,
for 2 secs.
9
The appropriate LED, F1 A51 or F2 A52, will light up. "---" is
displayed in the left-hand 7 segment display A4.
Â
Use the rotary knob A41 to select the desired secondary
parameter.
9
The secondary parameter code appears in the left-hand
7-segment display A4.
Â
To save, press the button, either F1 A50 or F2 A53, for 2
secs. again.
9
As confirmation, the appropriate LED, F1 A51 or F2 A52,
will flash twice.
If no input is made for 5 seconds during button
assignment, the operation will be cancelled.
Calling up the secondary parameters
Â
Press the appropriate button, F1 A50 or F2 A53, briefly.
9
The appropriate LED, F1 A51 or F2 A52, will light up. The
stored secondary parameter code appears in the left-hand
7-segment display A4.
Â
Use the rotary knob A44 to set the desired secondary pa-
rameter value.
Â
To save the value, press the appropriate button, F1 A50 or
F2 A53, again briefly.
9
As confirmation, the appropriate LED, F1 A51 or F2 A52,
will flash twice.
If the code "---" appears in the right-hand
7-segment display instead of the secondary pa-
rameter value, then this secondary parameter
is not available in the current mode.
4
Additional functions
Gas test
Â
Press the Gas test button A14.
9
The Gas test LED A15 lights up and the solenoid valve con-
nects.
The gas supply can be checked/adjusted. The function
remains active for 30 seconds and is then ended automa-
tically. The gas test can be aborted by pressing the Torch
button or by pressing the Gas test button again.
User Interface test
Â
Press the Crater fill A2 and Gas test A14 buttons simulta-
neously for 2 secs.
9
All the LEDs on the control panel light for approx 5 sec.
Control panel brightness
This function can be used to set the brightness of the com-
plete control panel.
Â
Press the „F1“ A50 and „F2“ A53 buttons simultaneously for
2 secs.
9
This shows the display release information.
Â
Increase or reduce the brightness by pressing the „F1“ A50
or „F2“ A53 buttons.
ii
ii
ii
ii