page 32
Temperature monitoring
The temperature of the heat sink is constantly monitored via a temperaure sensor. This sensor is a temperature
dependent resistor (NTC = negative temperature coefficient). The higher the temperature, the lower the resistance
value of the sensor.
Schematic
X3/2
X3/1
X1/12
X1/4
DCDRV1
ϑ
X2/12
X2/4
X3/2
X3/1
X1/12
X1/4
DCDRV2
ϑ
X3/12
X3/4
X5/1
X5/2
X6/11
X6/14
ACDRV1
ϑ
X4/11
X4/14
X5/1
X5/2
X6/11
X6/14
ACDRV2
ϑ
X5/11
X5/14
+3.3V
+3.3V
+3.3V
+3.3V
DSP
DK-MAPRO
The DSP is monitoring the temperature of the heatsink and as soon as the temperature reaches the programmed
maximum value, the machine will stop and displays
E01
(thermal overload).
The actual value of the temperature can be displayed at the front panel in menu Extras, Diagnosis, Module Tem-
peratures.
If one of the temperature sensors are faulty itself, then the machine will stop and
E13
(Temp.sensor error) is dis-
played.
Maximum temperatures
machine type
temp. primary
temp. secondary
V24
90 °C
87 °C
V27
91 °C
100 °C
V30, V40
93 °C
100 °C
V50
94 °C
100 °C