page 43
Identification power units
The pc-board DK-MAPRO is reading the configuration of the power units during the initialisation. On the primary
sides (pc-board DCDRV) the configuration is set by a DIP switch. On the secondary sides at AC/DC machines
(pc-board ACDRV) the configuration is set by a small jumper. The secondary side of the DC machines are the pc-
board KSDCN, which have a fixed (not setable) configuration.
If the DK-MAPRO detects a non valid configuration, it will display the error code
E25
(Powermodul detection).
Schematic
+3.3V
+3.3V
+3.3V
+3.3V
DSP
1
2
1
2
X1 / 4
X2 / 4
DCDR
V2
DK-MAPRO
X2 / 11
DCDR
V1
ACDR
V1
X1 / 11
X1 / 4
X1 / 11
X6 / 14
X6 / 10
X6 / 14
X6 / 10
ACDR
V2
X4 / 14
X4 / 10
X3 / 4
X3 / 11
X5 / 14
X5 / 10
primary side
(on DCDRV boards)
DIP 1 DIP 2 setting
type
OFF
OFF
240 A
V24, V40
OFF
ON
270 A
V27
ON
OFF
300 A
V30, V50
ON
ON
reserved
secondary side
(on ACDRV boards)
J1
setting
type
0 (jumper not set)
2 IGBT
V24, V40
1 (jumper set)
4 IGBT
V27, V30, V50