3DM
®
-GX5-35
DCP Manual
4.2.4
Get GNSS Data Base Rate (0x0C, 0x07)
Description
Get the base rate for the GNSS data in Hz.
Returns the value used for data rate calculations. See the
com-
mand.
Field Format
Field Length
Field
Descriptor
Field Data
Command
0x02
0x06
None
Reply Field 1:
ACK/ NACK
0x04
0xF1
U8 - Echo the command byte
U8 - Error code (0: ACK, non-zero: NACK)
Reply Field 2:
IMU Base Rate
0x04
0x84
U16 – GNSS data base rate (Hz)
Example
MIP Packet Header
Command/Reply Fields
Checksum
Sync1
Sync2
Desc.
Set
Payload
Length
Field
Length
Field
Desc.
Field Data
MSB
LSB
Command: Get
IMU Base Rate
0x75
0x65
0x0C
0x02
0x02
0x07
0xF1
0xF8
Reply Field 1:
ACK/NACK
0x75
0x65
0x0C
0x08
0x04
0xF1
Command echo: 0x07
Error code: 0x00
Reply Field 2:
GNSS Base
Rate
0x04
0x84
Base rate (Hz):
0x0x0004
0x76
0x14
Copy-Paste version of the command: “7565 0C02 0207 F1F8”
37