PASSWORD
It's possible to set a password from the App to block parameter modification and new keyfobs registration. PW setting
can be done from
MENU->SET UP MENU->Change password.
N.B.
If a new password is to be activated leave empty the textfield “Current Password”, if instead the password is to be
deactivated leave empty textfiels “New Password” and “Re-type Password”. If the password is to be changed fill all the
textfields.
CLOCK
To turn ON the switch, according to time charts defined using the “Remote Control ON/OFF TIME SWITCH” e
“ON/OFF TIME SWITCH” functions, Smat Sw utilize an integrated clock.
The App allow to update date and time of the clock. To do that, enter the “Clock Adjust” page (
Menu → Daily
schedule\Weekly schedule → Clock Adjust
) e press the “Device Time/Date Adjust“ button.
The internal clock is able to retain date and time for more than 24 hours in case of “black out”.
The eventual loss of date and time get signalled whit an alternated red/green led, that imply the permanent deactivation
of the switch till a new time update.
PARAMETERS MANAGEABLE BY THE APP
PARAMETER
Min-Max
Valore
iniziale
DESCRIPTION
1
COMMAND TYPE
1 - 2
1
Type of command attributed to key-fobs buttons:
1=Toggle (negation of the previous state),
2=Function_key (one button turns ON and another button turns OFF the
switch)
2
COMMAND MODE
1 - 2
1
Command mode: 1= single_click: a single push of the button is sufficient
to commute the switch.
2= double_click: the first push shows the state of the switch and a second
push (done while led is active) commute the state of the switch.
3
STATE RETENTION
0 - 2
0
State resume after a shut-down
0 = No,
1 = Yes, only if "MAX ON TIME"=0,
2 = Yes with turning off time “MAX ON TIME” reloaded.
4
MAX ON TIME
0 - 100000
0
Time after which the switch get automatically turned OFF, following an
ON command (0 = infinite).
5
MAX ON TIME UM
0 - 2
0
“OFF DELAY” unit of measurement: 0 = sec, 1 = min, 2 = hours.
6
ON TIME DC
0 - 100000
0
Duty Cycle ON time.
7
OFF TIME DC
0 - 100000
10
Duty Cycle OFF time.
8
DC TIME UM
0 - 2
0
“ON TIME DC” and “OFF TIME DC” unit of measurement;
0 = sec, 1 = min, 2 = hours.
9
CYCLE TIME
0 - 100000
0
“Pulse Switch” cycle duration.
10
CYCLE TIME UM
0 - 2
0
“CYCLE TIME” unit of measurement: 0 = sec, 1 = min, 2 = hours.
11
IMPULSE NUMBER
0 - 100000
0
Number of impulses (0 = infinite).
12
IMPULSE TIME
1 - 250
1
Impulse duration (s).
13
LED MODE
0 - 5
0
Smart Sw led signalling mode:
0
= led always on according to the raly state (ON = red,
OFF = green), *
1
= led flash to signal a relay state change:
(OFF->ON) = red flash, (ON->OFF) = green flash,
2
= if configured as “hour switch”:
green led ON when device OFF, red led ON when device ON;
else:
green led power ON, yellow (red+green) led supply and
relay ON;
3 = green led flash to signal command reception,
red led signal relay ON;
4
= green led during signal reception, red led during signal
transmission;
5
= leds always OFF.
* When the switch is configured as ON/OFF TIME SWITCH
led signaling is as parameter=0 even if the parameter value is different.
The keyfob led in this case indicate the switch ON/OFF ( green=
disactivated, red = activated)
14
DEL POWER ON
0 - 10
1
Relay activation delay after a “power outage” to avoid a simultaneous
activation of too many loads.