background image

7 of 20

Revision D, #10055, March 16th, 2005

   
  

SEARCH

 (

FROM

 148.516

MHZ

):  

  1)

START

        2)

GAIN

  3)

MIN

 

FREQ

   4)

MAX

 

FREQ

 

  5)

FREQ

 

STEP

   6)S

CAN

 

TIME

  7)

NOISE

 

THRESHOLD

1) Start

   
   

SEARCH

   148.220MH

Z

   ID    AH0=40

   0) P

AUSE

 S

CAN

      1) C

ODE

 S

ET

  

   2)S

HOW

 B

EEP

/ID/S

ENSOR

      

   3)S

ET

         4)GPS

   5) I

NC

. F

REQ

.   6)D

EC

. F

REQ

.   

   7)E

N

/D

IS

 N

OISE

 B

LANK

 8) I

NC

. G

AIN

    9)D

EC

. G

AIN

   
   

GAIN

 (87):

   (00-99) >

2)Gain

   
  

FOUND

:   I184 S121 10:54:21  

   148.220MH

Z

   C

ODE

   

GAIN

 =33

   0) P

AUSE

 S

CAN

 1) C

ODE

 S

ET

  

   2)S

HOW

 B

EEP

/ID/S

ENSOR

      3)S

ET

 

DELTA

        4)GPS   

   5) I

NC

. F

REQ

.   6)D

EC

. F

REQ

.    7)E

N

/D

IS

 N

OISE

 B

LANK

   8) I

NC

. G

AIN

    9)D

EC

. G

AIN

   
   

MIN

 

FREQ

 (148.000MH

Z

):

  (148-152.000MH

Z

) >

   
  

MAX

 

FREQ

 (152.000MH

Z

):

  (148-152.000MH

Z

) >

   
  

FREQ

 

STEP

 (002

K

H

Z

):

  (001-999

K

H

Z

) >

3)Min Freq

4)Max Freq

5)Freq Step

   
   

NOISE

 

THRESHOLD

 (40):

  (00-99) >

7)Noise Threshold

   
  S

CAN

 

TIME

 (2.2

S

):

  (0.1-9.9

SEC

) >

6)Scan Time

   
   P

AUSE

:   I999 S102 11:13:46

   148.220MH

Z

       AH0=40

   0) R

ESUME

  S

CAN

   1) C

ODE

 S

ET

  

   2)S

HOW

 B

EEP

/ID/S

ENSOR

   

   3)S

ET

 

DELTA

    4)GPS      5) I

NC

. F

REQ

   6)D

EC

. F

REQ

.    7)E

N

/D

IS

 N

OISE

 B

LANK

   8) I

NC

. G

AIN

    9)D

EC

. G

AIN

0)Pause

    Scan

Manual Mode > 2) Search

Summary of Contents for SRX 600

Page 1: ...1 of 20 Revision D 10055 March 16th 2005 Guide to the SRX 600 Keypad and LCD Display...

Page 2: ...ction or the entry of a numeric value It is necessary to spread out the information therefore the display shows what is referred to as a page whereby a menu item can link to more than one page Scroll...

Page 3: ...rd is always 123456 unless it is changed via Setup 3 Change Password Logging on via the factory password provides the ability to log on quickly as long as the factory password 123456 is being used Thi...

Page 4: ...2 Parity 3 Data Bits 4 Stop Bits SERIAL BAUD RATE 1 1 115200 2 57600 3 38400 4 19200 5 9600 6 4800 7 2400 8 1200 9 600 SERIAL PARITY 1 1 NONE 2 ODD 3 EVEN SERIAL DATA BITS 2 1 7 BITS 2 8 BITS SERIAL...

Page 5: ...TION 2 LOCAL DATE 3 LOCAL TIME 1 GMT Correction 2 Time GMT CORRECTION 05 00 HH MM 2 Local Date LOCAL DATE 17 06 04 DD MM YY 3 Local Time LOCAL TIME 11 24 33 24HH MM SS 3 Reset Change Password RESET PA...

Page 6: ...6 of 20 Revision D 10055 March 16th 2005 Manual mode MANUAL 1 CODE SET 2 SEARCH 3 SIGNAL 1 Code Set CODE SET 1 1 LOTEK 2 2 LOTEK3 3 LOTEK4 2 Search see page 7 3 Signal see page 8 CODE SET LOTEK 2 OR...

Page 7: ...ODE GAIN 33 0 PAUSE SCAN 1 CODE SET 2 SHOW BEEP ID SENSOR 3 SET DELTA 4 GPS 5 INC FREQ 6 DEC FREQ 7 EN DIS NOISE BLANK 8 INC GAIN 9 DEC GAIN MIN FREQ 148 000MHZ 148 152 000MHZ MAX FREQ 152 000MHZ 148...

Page 8: ...D AH0 40 1 CODE SET 2 SHOW BEEP ID SENSOR 3 SET DELTA 4 GPS 5 INC FREQ 6 DEC FREQ 7 EN DIS NOISE BLANK 8 INC GAIN 9 DEC GAIN 5 Noise Threshold 1 Start 3 Ant 2 Gain 4 Freq ANT 0 AH0 0 ASP8 1 8 GAIN 87...

Page 9: ...9 of 20 Revision D 10055 March 16th 2005 Codelog Mode CODELOG 1 CONFIG 2 SCAN 3 MASTER FTABLE 1 Config 1 see page 10 2 Scan see page 16 3 Master FTable see page 17...

Page 10: ...ALL 3 Freq CH 4 Ant Hydr see page 12 5 Filters see page 13 ADD FREQ CH 1 RADIO 2 ACOUSTIC 1 Add 2 View Modify ADD RADIO FERQ 11 148 152 000MHZ ADD ACOUSTIC FREQ 11 000 999KHZ 1 Radio 2 Acoustic 2 Scan...

Page 11: ...IME 1 Scan Time 2 Total Scan Time SCAN TIME 18 1S 00 1 99 9SEC TOTAL SCAN TIME 47 59 MM SS SCAN OPTIONS 1 TOA 2 CRTO 3 AGC 4 GPS CRTO 2 DIS 1 EN DIS 2 TIMEOUT GPS DIS CLK DIS POS 1 EN DIS CLK 2 EN DIS...

Page 12: ...ANT GAIN 3 RADIO MASTER GAIN 4 ACOUSTIC MASTER GAIN RADIO ANT GRP 123 1 8 HYDR GRP 567 1 8 ACOUSTIC MASTER HYDR 0 GRP 0 ASP8 1 8 NO 9 ASP8 GAIN 40 21 33 54 22 36 47 18 PORT 1 8 AH0 ANT GAIN 33 00 99 1...

Page 13: ...ADD 2 VIEW DEL SET ACCEPT CH ID 20 1 ADD 2 VIEW DEL SET REJECT ID 29 1 ADD 2 VIEW DEL SET ACCEPT ID 10 1 ADD 2 VIEW DEL 1 Add 2 View Del 1 Add 1 Add 1 Add 2 View Del 2 View Del 2 View Del ADD REJECT...

Page 14: ...WIDTH 4 SIGNAL STRENGTH DEV 2 Pulse Filter ECHO FILTER 020MS 000 255 NOISE THRESHOLD 30 00 99 MIN 2 0MS PULSE WIDTH 1 1 ENABLE 2 DISABLE MAX 18 SIGNAL S DEV 2 1 ENABLE 2 DISABLE 1 Echo 2 Noise Thresho...

Page 15: ...pe 3 Param C 6 0 34 0 50 1 MIN 2 MAX 3 LEVEL PSI 0 0 50 0 51 1 MIN 2 MAX 3 LEVEL ACT 0 1 2 1 MIN 2 MAX 3 LEVEL EMG 0 0 50 0 51 1 MIN 2 MAX 3 LEVEL 1 C 2 psi 3 ACT 4 EMG MIN 0006 0 C MAX 0034 0 C C LEV...

Page 16: ...D XXXXXX 2 Del All Data password DISPLAY SCROLL 0 OF 64 DETECTION 0 Pause Scan 2 View Codelog Mode 2 Scan 2 Scan PAUSE I243 S100 14 22 33 148 220MHZ CH800 AMG 33 0 RESUME SCAN 1 FILTERS 2 VIEW 3 SET D...

Page 17: ...ion D 10055 March 16th 2005 Codelog Mode 3 Master Ftable MASTER FTABLE 1 UUC FREQ 2 VIEW MASTER FTABLE 1 UUC Freq UUC FREQ 150 000MHZ 148 152 000 2 Master F Table 148 000MHZ CH001 1 IS IN CFG 1 2 4 3...

Page 18: ...18 of 20 Revision D 10055 March 16th 2005 SET Delta SET DELTA 1 FREQ 2 GAIN DELTA FREQ 001 KHZ 001 999 DELTA GAIN 02 01 99...

Page 19: ...20 Revision D 10055 March 16th 2005 GPS Before GPS fix After GPS fix Other possible message TEST GPS TIME POSITION TEST GPS 15 34 27 GMT 44 0627687 79 4467891 TEST GPS TIME POSITION ANTENNA OPEN DETE...

Page 20: ...20 of 20 Revision D 10055 March 16th 2005...

Reviews: