©Copyright LOTRONIC 2016
8ROLL-FX
Page 3
• 4-Button menu system LED Display making it easy to navigate
• Display inversion
Specifications
Power supply ................................................................................................... 100-240Vac 50/60Hz
Consumption ............................................................................................................................ 80W
Light source .......................................................................................... 8x 10W LED (RGBW 4-in-1)
Single beam angle ........................................................................................................................ 5°
Head movement .................................................................. PAN : 540°, TILT1/2 : infinite rotation
Dimensions ....................................................................................................... 210 x 170 x 350mm
Weight ........................................................................................................................................ 4kg
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure
and able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times
the weight of the unit when installing the fixture.
The equipment must be fixed by professionals at a place where is out of the reach of people and where nobody can
pass by or under it.
ORIENTATION
This fixture may be mounted in any position provided there is adequate room for ventilation.
Fuse Replacement
Disconnect the power cord before replacing a fuse and always replace with the same type fuse.
With a flat head screwdriver wedge the fuse holder out of its housing.
Remove the damaged fuse from its holder and replace with exactly the same type of fuse.
Insert the fuse holder back in its place and reconnect power.
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade
cables that can carry a high quality signal and are less prone to electromagnetic interference.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
CAUTION
Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a
ground loop, and your fixture may perform erratically. Test cables with an ohm meter to check correct polarity and
to make sure the pins are not grounded or shorted to the shield or each other.
INPUT
COMMON
DMX +
DMX-
Resistance 120 ohm
1/ 4w between pin 2
(DMX-) and pin 3
(DMX+) of the last
fixture.